background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

MODEL NO.

CI1500DVF Series

MANUFACTURED AT:

Burlington, WA

FOR USE WITH NATURAL GAS.                        EQUIPE POUR GAZ NATUREL
ALTITUDE
MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
ENTRÉE MIN (BTUH)

0-4500 FT (0-1370 M)

4.5”

3.5”

#37

28,000

17,500

ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL     

-UNIT/APPAREIL:  MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS

MINIMUM

SIDEWALLS

FLOOR

2”
0”

CLEARANCES TO

CEILING OR ALCOVE HEIGHT

BACK/CORNER 45

°

62”

4”

COMBUSTIBLE

MATERIAL

VENT SURFACES:  TOP

                                     SIDES

                                         BOTTOM

3”
1”
1”

ALCOVE MAXIMUM DEPTH

48”

DEGAGEMENT

MUR ADJACENTS

PLANCHER

50.8mm

0mm

MINIMUM DE

PLAFOND OU HAUTEUR D'ALCÔVE

EN ARRIÈRE ET COIN 45 ANGLE

1574.8mm

101.6mm

MATERIAUX

COMBUSTIBLES

SURFACES D’AERATION:  DESSUS

                                             COTES

                                        BAS

76.2mm
25.4mm
25.4mm

PROFONDEUR D'ALCÔVE MAXIMALE

1219.2mm

DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE

VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.

FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN

COMBUSTIBLE SOLIDE.

FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.

N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.

“CAUTION: 

Do not operate the appliance with glass removed, cracked or broken.

Replacement of panel should be done by a licensed or qualified service person.”

“This appliance is equipped at the factory for use with natural gas only. Units using

propane must be field converted using the LP conversion kit, P/N LB-102158A”

FINAL INSPECTION BY:

ANSI Z21.88-2002

CSA 2.33-2002

CAN/CGA-2.17-M91

VENTED GAS STOVE HEATERS

FOYER DE CHAUFFAGE AU GAZ A EVACUATION      P/N 9-1452A

SERIAL NUMBER/NOMBRE DE SERIE

XXXXX XXXXX

IIIIIIIIIIIIIIIIIIII

XXXXXXXXXXXXXXXX

P/N 9-1452A

MODEL NO.

CI2500DVF Series

MANUFACTURED AT:

Burlington, WA

FOR USE WITH NATURAL GAS.                        EQUIPE POUR GAZ NATUREL
ALTITUDE
MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
ENTRÉE MIN (BTUH)

0-4500 FT (0-1370 M)

4.5”

3.5”

.121

38,500

25,500

ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL     

-UNIT/APPAREIL:  MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS

MINIMUM

SIDEWALLS

FLOOR

2”
0”

CLEARANCES TO

CEILING OR ALCOVE HEIGHT

BACK/CORNER 45

°

62”

4”

COMBUSTIBLE

MATERIAL

VENT SURFACES:  TOP

                                     SIDES

                                         BOTTOM

3”
1”
1”

ALCOVE MAXIMUM DEPTH

48”

DEGAGEMENT

MUR ADJACENTS

PLANCHER

50.8mm

0mm

MINIMUM DE

PLAFOND OU HAUTEUR D'ALCÔVE

EN ARRIÈRE ET COIN 45 ANGLE

1574.8mm

101.6mm

MATERIAUX

COMBUSTIBLES

SURFACES D’AERATION:  DESSUS

                                             COTES

                                        BAS

76.2mm
25.4mm
25.4mm

PROFONDEUR D'ALCÔVE MAXIMALE

1219.2mm

DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE

VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.

FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN

COMBUSTIBLE SOLIDE.

FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.

N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.

“CAUTION: 

Do not operate the appliance with glass removed, cracked or broken.

Replacement of panel should be done by a licensed or qualified service person.” .”
“This appliance is equipped at the factory for use with natural gas only. Units using

propane must be field converted using the LP conversion kit, P/N LB-102158B”

FINAL INSPECTION BY:

ANSI Z21.88-2002

CSA 2.33-2002

CAN/CGA-2.17-M91

VENTED GAS STOVE HEATERS

FOYER DE CHAUFFAGE AU GAZ A EVACUATION      P/N 9-1452F

SERIAL NUMBER/NOMBRE DE SERIE

XXXXX XXXXX

IIIIIIIIIIIIIIIIIIII

XXXXXXXXXXXXXXXX

P/N 9-1452F

Summary of Contents for 775

Page 1: ...OTICE POURRÉDUIREAUMINIMUMLERISQUED INCENDIE OUPOURÉVITERTOUTDOMMAGEMATÉRIEL TOUTE BLESSURE OU LA MORT POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser d essencenid autrevapeursouliquidesinflammablesdans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE SÉCURITÉ Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur Ne pas vous...

Page 2: ...ts Note Installation and repair should be per formed by a qualified service person The appliance should be inspected annually by a qualified professional service technician Morefrequentinspectionsandcleaningsmay berequiredduetoexcessivelintfromcarpet ing bedding material etc It is imperative that the control compartment burners and circulating air passage ways of the appliance be kept clean S assu...

Page 3: ...Pa 10 5 WC 2 61 kPa Propane 11 0 WC 2 73 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 1 6 WC 40 kPa Hi 3 5 WC 87 kPa Propane Lo 6 3 WC 1 57 kPa Hi 10 0 WC 2 49 kPa Table 3 Ne pas se servir de cet appareil s il a été plongé dans l eau complètement ou en partie Appeler un technicien qualifié pour inspecterl appareiletremplacertoutepartie du ...

Page 4: ...2 mm SPECIFICATIONS CI1500DVF CI2500DVF Min Max BTU hr Input NG 17 500 28 000 25 500 38 500 Min Max BTU hr Input LP 20 500 27 000 26 500 34 500 DV Vent Size 4 inner 6 5 8 outer Room Fan CFM 150 150 Weight lb 206 290 EFFICIENCIES CI1500DVF CI2500DVF 67 NG 65 LP 67 NG 64 LP Steady State Efficiency Note Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject ...

Page 5: ...00DVF CI2500DVF A minimum 10 254 mm B minimum 14 1 4 362 mm 17 1 4 438 mm C minimum 15 7 8 403 mm 19 483 mm D minimum 4 102 mm 4 102 mm E minimum 2 51 mm 2 51 mm F minimum 4 102 mm 4 102 mm G minimum 0 0 mm 0 0 mm H minimum 62 1575 mm 62 1575 mm I minimum 28 1 2 724 mm 34 1 2 876 mm J MAXIMUM 48 1219 mm 48 1219 mm 10 254 mm Figure 2 CLEARANCES TO COMBUSTIBLE MATERIALS FLOOR PROTECTION The location...

Page 6: ...nalvent location restrictions refer to Figure 5 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances These instructions should be used as a guidelineanddonotsupersedelocalcodesin anyway Installventaccordingtolocalcodes these instructions the current National Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CGA B149 1 and B149 2 in Canada Side Elevation View QUESTION...

Page 7: ... i w t n e v e r p o t d e d n e m m o c e r m m 9 2 2 9 n o i t a s n e d n o c w o d n i w t i f f o s d e t a l i t n e v o t e c n a r a e l c l a c i t r e V D l a t n o z i r o h a n i h t i w l a n i m r e t e h t e v o b a d e t a c o l r e t n e c e h t m o r f m m 8 5 4 s e h c n i 8 1 f o e c n a t s i d l a n i m r e t e h t f o e n i l m m 8 5 4 8 1 m m 8 5 4 8 1 t i f f o s d e t a l...

Page 8: ...sediment and more Certainly no one unfamiliar and unqualified should attempt sizing or installing gas piping The gas supply line should be plumbed from thefuelsourcetotheareawheretheappliance is to be installed per requirements outlined in NFPA 54 latest edition USA and B149 latest edition Canada Open both Latches as shown WARNING NEVER OPERATE APPLIANCE WITHOUTTHEFRONTGLASSENCLOSURE PANEL IN PLAC...

Page 9: ...actory on both models see Figure 11 SIT Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile TH TP TH TP ON OFF SWITCH OPTIONAL THERMOSTAT OR REMOTE SWITCH CONTROL RECEIVER Figure 10 Blower Wiring Diagram RELIEF DOOR Theloweraccess doorhingesopen to access Valve Controls Lower Access Door Figure 12 Step 8 INS...

Page 10: ...ce for Natural Gas and 36 for Propane Gas before the first elbow The horizontal run may extend up to 20 feet 6 meters and include a vertical rise of up to 40 feet 12 meters see Figure 13 Horizontal termination must meet the criteria shown in Figures 4 and 5 Approved vent systems must terminate above and including the heavy line in Figure 13 Two 45 degree elbows may be substituted for each single 9...

Page 11: ...nversion Kit for 6 I D 1 insulation SV4CCK2 Factory Built Chimney Conversion Kit for 7 I D 1 insulation 8 I D 1 insulation 6 I D 2 insulation SV4CCK3 Factory Built Chimney Conversion Kit for 10 I D 1 insulation 7 I D 2 insulation 8 I D 2 insulation Model Brand SIMPSON DURA VENT Description 934 Masonry Chimney Conversion Kit 931 Factory Built Chimney Conversion Kit A for 6 I D 932 Factory Built Chi...

Page 12: ...ack 904B 24 Pipe Length Black SV4L36 36 Pipe Length Galvanized 903 36 Pipe Length Galvanized SV4LB36 36 Pipe Length Black 903B 36 Pipe Length Black SV4L48 48 Pipe Length Galvanized 902 48 Pipe Length Galvanized SV4LB48 48 Pipe Length Black 902B 48 Pipe Length Black SV4LA 6 Adj Pipe Length Galvanized 908 6 Adj Pipe Length Galvanized SV4LBA 6 Adj Pipe Length Black N A N A SV4LA12 12 Adj Pipe Length ...

Page 13: ...rol valve is located in the lower control compartment To access the valve open the lower access door The millivolt control valve has a 3 8 10 mm NPT thread inlet port fitting Figure 20 Ember Strip Rear Log Figure 21 Left Front Log Figure 22 2 Place the largest log onto the rear log stoppers see Figure 20 Ensure that the grooves on the bottom of the log aligns onto the corresponding places on the r...

Page 14: ...the cor responding pin on the rear log and align it withtheindentationonfrontleftlogasshown in Figure 26 8 Install the front right twig onto the cor responding pin on the right front log Align thetwigwiththeindentationonthefrontright log as shown in Figure 27 9 Place the glowing embers on the burner as shown in Figures 28 29 One package of ember material has been included with this log set You wil...

Page 15: ... switch MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Figure32 Proper PilotFlameAppearance Figure 33 Burner Flame Appearance Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be yellow Air shutter gap should be increased If air shutter is open too far Flame will be blue Air shutter ...

Page 16: ...Y HEAVY AND MAY REQUIRE A MINIMUM OF TWOPEOPLETOLIFT ONEPERSONONEACH SIDE THE CI1500 SERIES CAST TOP WEIGHS 20 POUNDS AND THE CI2500 SERIES CAST TOP WEIGHS 40 POUNDS B Locate the ash lip from packaging Step 2 Remove the 2 bolts from the tapped holes in theashlip Aligntheashlipbelowthefirebox as shown in Figure 36 the tapped holes in ash lip should align with corresponding slots below firebox Reins...

Page 17: ...U GAZ A EVACUATION P N 9 1452A SERIAL NUMBER NOMBRE DE SERIE XXXXX XXXXX IIIIIIIIIIIIIIIIIIII XXXXXXXXXXXXXXXX P N 9 1452A MODEL NO CI2500DVF Series MANUFACTURED AT Burlington WA FOR USE WITH NATURAL GAS EQUIPE POUR GAZ NATUREL ALTITUDE MIN GAS SUPPLY PRESS WC PRESS MIN D ALIMENTATION CE MANIFOLD PRESSURE WC PRESSION CE TUBULURE CE MANUFACTURER S RECOMMENDED ORIFICE SIZE DIMENSION DE L INJECTEUR R...

Page 18: ...P N 775 147M REV C 11 2004 1110 West Taft Avenue Orange CA 92865 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information ...