 Input (BTU/HR) Manually-Modulated Gas 

Valves (millivolt models)

Models

Nat. Gas

Propane

CI1500DVF

17,500 to

28,000

20,500 to

27,000

CI2500DVF

25,500 to

38,500

26,500 to

34,500

Table 1

PACKAGING LIST

The assembled vented gas stove heater is 
packaged with:
one -  log set located in fi rebox
one -  ember strip located beneath stove 
   

body (on pallet)

one -  bag of glowing embers located in
   

the fi rebox

one -  envelope containing the literature
   

package which consists of the

   

homeowner's manual, installation 

   

instructions and warranty; located 

   

on the top of the fi rebox

one -  cast iron top
one -  trivet
one -  natural gas to propane conversion kit
one -  ash lip
one -  lower access door
four -  leg levelers

These appliances comply with National 
Safety Standards and are tested and listed 
by OMNI-Test Laboratories Inc.; Beaverton, 
Oregon (Report No. 116-S-08-05) to ANSI 
Z21.88-2002 (in Canada, CSA-2.33-2002), 
and CAN/CGA-2.17-M91 in both USA and 
Canada, as vented gas heaters.  

TABLE OF CONTENTS 

Packaging ......................................page  2
Introduction ...................................page  2
General Information .......................page  2
High Altitude ..................................page  3
Location .........................................page  3
Specifi cations .................................page  4
Appliance and Vent Clearances ......page  5
Manufactured Home Requirements ...page 6
Vent Termination Clearances  .........page  6
Typical Installation Sequence  ........page  8

Step 1 Preparation ...........................page 8
Step 2 Remove Packaging .................page  8
Step 3 Remove Stove From Pallet  ....page  8
Step 4 Remove Front Glass ...............page  8
Step 5 Remove Firebox Contents ......page  8
Step 6 Remove Cardboard Pkg. ........page  9
Step 7 Install LP Conv./Options .........page  9
Step 8 Install Lower Access Door .........page 9
Step 9 Install Venting .........................page  9
Step 10 Connect Gas Line ..................page  13

Step 11 Install Log Set .......................page  13
Step 12 Reinstall Front Glass .............page  14
Step 13 Perform Leak Test .................page  14
Step 14 Check Appliance Operation ...page  14
Step 15 Adjust Burner  .......................page  15
Step 16 Install Top, Trivet & Ash Lip ..page  16
Rating Plates .......................................page  17

INTRODUCTION 

These vented gas heaters are sealed combus-
tion, air circulating gas stoves designed for 
residential applications. These appliances 
must be installed with "Security Secure 
Vent

TM

" or "Simpson Dura Vent" brand vent 

systems routed to the outside atmosphere 
(other brands may not be used).

Millivolt  appliances are designed to oper-
ate on natural or propane gas. A millivolt 
gas control valve with piezo ignition system 
provides safe, effi cient operation. External 
electrical power is required to operate the 
optional blower if installed on these units.

Note: 

Installation and repair should be per-

formed by a qualifi ed service person. The 
appliance should be inspected annually by 
a qualifi ed professional service technician. 
More frequent inspections and cleanings may 
be required due to excessive lint from carpet-
ing, bedding material, etc. It is imperative 
that the control compartment, burners and 
circulating air passage ways of the appliance 
be kept clean.

S'assurer que le brùleur et le compartiment 
des commandes sont propres.  Voir les 
instructions d'installation et d'utilisation qui 
accompagnent l'appareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct 
the front openings of the appliance.

These appliances are designed to operate 
on natural or propane gas only.

Table 1 shows the BTU input for each 
model:

Please read and understand these 
instructions before beginning your 
installation.

This installation manual will help you obtain 
a safe, effi cient, dependable installation for 
your appliance and vent system. 

GENERAL INFORMATION

These millivolt models come standard with 
the manually-modulated gas valve; fl ame 
appearance and heat output can be controlled 
at the gas valve.

DO NOT ATTEMPT TO ALTER OR MODIFY 
THE CONSTRUCTION OF THE APPLIANCE OR ITS 
COMPONENTS. ANY MODIFICATION OR ALTERA-
TION MAY VOID THE WARRANTY, CERTIFICATION 
AND LISTINGS OF THIS UNIT.

CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-
FACTURED BY LENNOX HEARTH PRODUCTS.

 

When you purchased your new gas fi red heater, you joined the ranks of thousands of 

concerned individuals whose answer to their home heating needs refl ects their concern for 
aesthetics, effi ciency and our environment. We extend our continued support to help you 
achieve the maximum benefi t and enjoyment available from your new gas fi red heater. It 
is our goal at Lennox Hearth Products to provide you, our valued customer, with an appli-
ance that will ensure you years of trouble free warmth and pleasure. 
 

Thank you for selecting a Lennox Hearth Products gas fi red heater as the answer to 

your home heating needs.

Sincerely, 
All of us at Lennox Hearth Products

These Millivolt appliances are listed by 
OMNI-Test Laboratories Inc. for instal-
lation in bedrooms and manufactured 
(mobile) homes.

Installation must conform to local codes. In 
the absence of local codes, installation must 
comply with the current National Fuel Gas 
Code, ANSI Z223.1. (In Canada, the current 
CAN-1 B149 installation code.)  Electrical 
wiring must comply with the National Electri-
cal Code ANSI/ NFPA 70 - latest edition.  In 
Canada, the current CSA C22-1 Canadian 
Electrical Code - latest edition.

Summary of Contents for 775

Page 1: ...OTICE POURRÉDUIREAUMINIMUMLERISQUED INCENDIE OUPOURÉVITERTOUTDOMMAGEMATÉRIEL TOUTE BLESSURE OU LA MORT POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser d essencenid autrevapeursouliquidesinflammablesdans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE SÉCURITÉ Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur Ne pas vous...

Page 2: ...ts Note Installation and repair should be per formed by a qualified service person The appliance should be inspected annually by a qualified professional service technician Morefrequentinspectionsandcleaningsmay berequiredduetoexcessivelintfromcarpet ing bedding material etc It is imperative that the control compartment burners and circulating air passage ways of the appliance be kept clean S assu...

Page 3: ...Pa 10 5 WC 2 61 kPa Propane 11 0 WC 2 73 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 1 6 WC 40 kPa Hi 3 5 WC 87 kPa Propane Lo 6 3 WC 1 57 kPa Hi 10 0 WC 2 49 kPa Table 3 Ne pas se servir de cet appareil s il a été plongé dans l eau complètement ou en partie Appeler un technicien qualifié pour inspecterl appareiletremplacertoutepartie du ...

Page 4: ...2 mm SPECIFICATIONS CI1500DVF CI2500DVF Min Max BTU hr Input NG 17 500 28 000 25 500 38 500 Min Max BTU hr Input LP 20 500 27 000 26 500 34 500 DV Vent Size 4 inner 6 5 8 outer Room Fan CFM 150 150 Weight lb 206 290 EFFICIENCIES CI1500DVF CI2500DVF 67 NG 65 LP 67 NG 64 LP Steady State Efficiency Note Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject ...

Page 5: ...00DVF CI2500DVF A minimum 10 254 mm B minimum 14 1 4 362 mm 17 1 4 438 mm C minimum 15 7 8 403 mm 19 483 mm D minimum 4 102 mm 4 102 mm E minimum 2 51 mm 2 51 mm F minimum 4 102 mm 4 102 mm G minimum 0 0 mm 0 0 mm H minimum 62 1575 mm 62 1575 mm I minimum 28 1 2 724 mm 34 1 2 876 mm J MAXIMUM 48 1219 mm 48 1219 mm 10 254 mm Figure 2 CLEARANCES TO COMBUSTIBLE MATERIALS FLOOR PROTECTION The location...

Page 6: ...nalvent location restrictions refer to Figure 5 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances These instructions should be used as a guidelineanddonotsupersedelocalcodesin anyway Installventaccordingtolocalcodes these instructions the current National Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CGA B149 1 and B149 2 in Canada Side Elevation View QUESTION...

Page 7: ... i w t n e v e r p o t d e d n e m m o c e r m m 9 2 2 9 n o i t a s n e d n o c w o d n i w t i f f o s d e t a l i t n e v o t e c n a r a e l c l a c i t r e V D l a t n o z i r o h a n i h t i w l a n i m r e t e h t e v o b a d e t a c o l r e t n e c e h t m o r f m m 8 5 4 s e h c n i 8 1 f o e c n a t s i d l a n i m r e t e h t f o e n i l m m 8 5 4 8 1 m m 8 5 4 8 1 t i f f o s d e t a l...

Page 8: ...sediment and more Certainly no one unfamiliar and unqualified should attempt sizing or installing gas piping The gas supply line should be plumbed from thefuelsourcetotheareawheretheappliance is to be installed per requirements outlined in NFPA 54 latest edition USA and B149 latest edition Canada Open both Latches as shown WARNING NEVER OPERATE APPLIANCE WITHOUTTHEFRONTGLASSENCLOSURE PANEL IN PLAC...

Page 9: ...actory on both models see Figure 11 SIT Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile TH TP TH TP ON OFF SWITCH OPTIONAL THERMOSTAT OR REMOTE SWITCH CONTROL RECEIVER Figure 10 Blower Wiring Diagram RELIEF DOOR Theloweraccess doorhingesopen to access Valve Controls Lower Access Door Figure 12 Step 8 INS...

Page 10: ...ce for Natural Gas and 36 for Propane Gas before the first elbow The horizontal run may extend up to 20 feet 6 meters and include a vertical rise of up to 40 feet 12 meters see Figure 13 Horizontal termination must meet the criteria shown in Figures 4 and 5 Approved vent systems must terminate above and including the heavy line in Figure 13 Two 45 degree elbows may be substituted for each single 9...

Page 11: ...nversion Kit for 6 I D 1 insulation SV4CCK2 Factory Built Chimney Conversion Kit for 7 I D 1 insulation 8 I D 1 insulation 6 I D 2 insulation SV4CCK3 Factory Built Chimney Conversion Kit for 10 I D 1 insulation 7 I D 2 insulation 8 I D 2 insulation Model Brand SIMPSON DURA VENT Description 934 Masonry Chimney Conversion Kit 931 Factory Built Chimney Conversion Kit A for 6 I D 932 Factory Built Chi...

Page 12: ...ack 904B 24 Pipe Length Black SV4L36 36 Pipe Length Galvanized 903 36 Pipe Length Galvanized SV4LB36 36 Pipe Length Black 903B 36 Pipe Length Black SV4L48 48 Pipe Length Galvanized 902 48 Pipe Length Galvanized SV4LB48 48 Pipe Length Black 902B 48 Pipe Length Black SV4LA 6 Adj Pipe Length Galvanized 908 6 Adj Pipe Length Galvanized SV4LBA 6 Adj Pipe Length Black N A N A SV4LA12 12 Adj Pipe Length ...

Page 13: ...rol valve is located in the lower control compartment To access the valve open the lower access door The millivolt control valve has a 3 8 10 mm NPT thread inlet port fitting Figure 20 Ember Strip Rear Log Figure 21 Left Front Log Figure 22 2 Place the largest log onto the rear log stoppers see Figure 20 Ensure that the grooves on the bottom of the log aligns onto the corresponding places on the r...

Page 14: ...the cor responding pin on the rear log and align it withtheindentationonfrontleftlogasshown in Figure 26 8 Install the front right twig onto the cor responding pin on the right front log Align thetwigwiththeindentationonthefrontright log as shown in Figure 27 9 Place the glowing embers on the burner as shown in Figures 28 29 One package of ember material has been included with this log set You wil...

Page 15: ... switch MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Figure32 Proper PilotFlameAppearance Figure 33 Burner Flame Appearance Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be yellow Air shutter gap should be increased If air shutter is open too far Flame will be blue Air shutter ...

Page 16: ...Y HEAVY AND MAY REQUIRE A MINIMUM OF TWOPEOPLETOLIFT ONEPERSONONEACH SIDE THE CI1500 SERIES CAST TOP WEIGHS 20 POUNDS AND THE CI2500 SERIES CAST TOP WEIGHS 40 POUNDS B Locate the ash lip from packaging Step 2 Remove the 2 bolts from the tapped holes in theashlip Aligntheashlipbelowthefirebox as shown in Figure 36 the tapped holes in ash lip should align with corresponding slots below firebox Reins...

Page 17: ...U GAZ A EVACUATION P N 9 1452A SERIAL NUMBER NOMBRE DE SERIE XXXXX XXXXX IIIIIIIIIIIIIIIIIIII XXXXXXXXXXXXXXXX P N 9 1452A MODEL NO CI2500DVF Series MANUFACTURED AT Burlington WA FOR USE WITH NATURAL GAS EQUIPE POUR GAZ NATUREL ALTITUDE MIN GAS SUPPLY PRESS WC PRESS MIN D ALIMENTATION CE MANIFOLD PRESSURE WC PRESSION CE TUBULURE CE MANUFACTURER S RECOMMENDED ORIFICE SIZE DIMENSION DE L INJECTEUR R...

Page 18: ...P N 775 147M REV C 11 2004 1110 West Taft Avenue Orange CA 92865 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information ...

Reviews: