Heating
Reset
Welded length
Cursor will blink
on the display
H
Welding Temperature
Set the welding temperature with the , keys. The temperature is
dependent on the material and the ambient temperature. The in-put SET value
will be shown on the display. Switch on the heating by pressing the and
keys simultaneously. Heating-up time approx. 5 mins. (SET value not achie-
ved, see airflow).
Airflow
+
+
–
H
H
Drive
ON / OFF
SET value setting
–
+
M
ON / OFF
SET value setting
–
+
+
&
H
6
WELDING PARAMETERS
LEISTER Varimat V
Welding speed
Depending on the film or geomembrane liner and the influence of the weather,
set the welding speed with the keys. The in-put SET value will be shown
on the display.
+
–
H
2 x
Important note:
During the heating-up process, the airflow is adjusted automatically
to 100%. Only after reaching the SET temperature, the pre-set airflow
in %, is taken over (element protection). If the SET temperature has
not been achieved, adjust the airflow to 80% before switching on the
heating element.
–
+
M
&
+