FAULT FINDING ACTIONS
LEISTER Varimat V
5
Automatic starter reason for fault
Drive motor
does not start automatically
after the nozzle has been positioned
•
Sensor (6)
set incorrectly
Action
adjust Sensor
– Switch off
main switch (3)
–
Remove sensor covering (32)
– Lower the
hot air blower (8)
and guide it to the left until it locks
–
Locking lever (11)
must click in
– Loosen
locking screw for sensor (7)
– Push
sensor (6)
to
tool holder (10)
IMPORTANT! Distance between tool holder and sensor > 0,2 – 0,5 mm max.
– Tighten locking
screw for sensor (7)
– Fix
sensor covering (32)
– Move the
hot air blower (8)
out until it locks and swivel up
– Make a functional test
If malfunction is still present, contact your Service Center.
Error 100/ 101/ 102
Measures
• Check blower (air must be flowing out of nozzle)
• If malfunction is still present, contact your Service Center