![Leister TAPEMAT Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/leister/tapemat/tapemat_operating-instructions-manual_1873906013.webp)
13
Leister TAPEMAT
Hot-Air welding machine
TAPEMAT:
Manually guided automatic hot-air welding machine for welding PVC straps from 45 mm to max.
50 mm wide – as the reinforcement for tarpaulins – on horizontal and level surfaces.
TAPEMAT Spriegel:
: Manually guided automatic hot-air welding machine for welding PVC straps (reinforcement
strips) 100 mm and 125 mm wide – as the reinforcement for tarpaulins – on horizontal and level surfaces.
Application
Please read operating instructions carefully before use
and keep for future reference.
Operating Instructions
(Translation of the original operating instructions)
GB
Danger to life if you
open the equipment, since this reveals current-conducting
components and connections.
Remove the mains plug from the plug socket before opening the equipment.
Incorrect use of the hot air tool can present a
fire and explosion hazard
especially near combustable materials and explosive gases.
Do not touch the element housing and nozzle when hot as they can cause
burns
.
Allow the tool to cool down. Do not point the hot air flow at people or animals.
Warning
Connect tool to a
receptacle with protective earth terminal
. Any interruption of
the protective conductor inside or outside the tool is dangerous !
Use only extension cables/cords with protective conductor!
Conductor cross-section: 4 x 2.5mm
2
The tool must be operated
under supervision.
Heat can ignite flammable materials which are not in view.
The machine may only be used by
qualified specialists
or under their supervision.
Children are not authorized to use this machine.
For personal protection, we strongly recommend the tool be connected to an
RCCB
(
R
esidual
C
urrent
C
ircuit
B
reaker) before using it on construction sites.
The mains voltage
, that is quoted on the equipment must agree with the mains
voltage.
IEC/EN 61000-3-11; Z
max
= 0.039
Ω
+ j 0.024
Ω
. If necessary, consultate supply
authority.
In the case of
line/mains power failure
extract hot-air blower and set
main switch to position
0
Protect the tool
from damp and wet.
FI
230
400
Caution
The equipment must not be lifted using the additional weight.
Summary of Contents for TAPEMAT
Page 49: ...49 21 50 5 9 28 51 5 1 2 21 17 17 24 23 3 7 5 32 34 33 22 28 17 4 6 1 FI 120 230...
Page 50: ...50 3 I 4 7 5 6 12 22 9 31 23 24 7 8 10 8 3 0 3 7 6 12 22 22 22 4 9 3 0 3 I 4...
Page 51: ...51 28 8 10 3 0 9 29 28 28 30 0 5 29 28 9 31 23 24 0 5 mm 3 28 24 23 30 29 9 8 31...
Page 52: ...52 Leister Leister TAPEMAT 8 9 1 TAPEMAT 24 1...
Page 53: ......
Page 54: ......
Page 55: ......