ProVision 3 Installation Manual
8100-35521-00
Rev. A0
Leidos Security Detection & Automation, Inc.
–
Proprietary
Page 90 of 119
© 2020 Leidos. All rights reserved
Figure 100: Pre-cal and VCO Cal
16.
After review the test results click save baseline, this is only allowable after the test results have be
reviewed and are passing.
17.
Click the
Close Window icon
(white X with a red background) at upper right to close
SVDiagnostics.
Auto Test Verification with Field Service Laptop
1.
Press Ctrl+Alt+Shift+X to close the lane application and return to the Field Service Tool window.
2.
In the Field Service Tool
window, click
Start Auto test
.
3.
On the left side of the Auto test window, click
Software tests
and verify that all software tests pass.
Correct any failures as needed.
4.
On the left side of the Auto test window, click
Hardware tests
and verify that all hardware tests pass.
Correct any failures as needed.
5.
Test the system in accordance with customer requirements to verify detection results.