Figure 37: Column Bolt Direction
9.
Using a 24mm socket, torque three of the column base bolts to 94.9 Nm (70.0 ft-lb) in the following
order: first 1, then 2, then 3 (refer to the following figure). Leave bolt 4 (the bolt diagonally opposite
the leveling foot) loose.
Figure 38: Bolts 1
–
3 Torqued on Left (Top) and Right (Bottom) Columns
10.
Loosen the shipping leg top bolts but do not remove them.