The Leica DMI 6000 Microscope 

Turning the right hand microscope focus control clockwise (away from you) raises 
the objective (up). Turning the focus control anti-clockwise (towards you) lowers 
the objective downwards (down).  

The SmartMove remote control module on the desktop controls the motorised XY 
stage and the motorised z focus. The top rotary knob controls stage travel in X 
(across) and the bottom rotary knob controls stage travel in Y (up/down). The 
rear rotary knob is the z focus. 

Change objectives using the LAS AF software as you can directly select the 
objective you want and it will allow you to go from air to oil objectives via a 
software ‘yes/no’ prompt. 

The microscope uses standard Zeiss 518F immersion oil. If oil drips off the bottle 
applicator in use, you have too much oil on it. To avoid oil contamination of air 
objectives, never change from an oil to an air objective when focussed on the 
specimen under oil (you can start with the low power air objective and then move 
up to the hi-power oil objective). 

The large HC PL Apo x63 Mott Corr Water CS2 Objective with cable control of the 
correction collar is for use with water immersion only – not 518F immersion oil. 
Make sure you don’t select it in error when using the 63x oil objective. The water 
immersion objective is easy to spot as the large correction collar motor sticks out 
of the side of the objective. 

For live cell work switch on the 37oC stage incubator at least 2 hours before use, 
or ideally the night before. Type the words ‘Live Cell’ in your booking to tell other 
prior SP8 users that the 37oC incubator heater is being left on for your later live 
cell imaging slot. 

We have a small 5% CO2 in air gas cylinder that can be used with the SP8 live cell 
incubator. CO2 can be used with 2.5cm Mattek petri dishes, Labtek 3x1” glass 
slides and multiwall plates using the appropriate stage insert. 

 

Summary of Contents for SP8-X

Page 1: ...Page 1 Wellcome Trust Centre for Human Genetics Cellular Imaging Microscopy Core The Leica SP8 X SMD Confocal Abridged INSTRUCTIONS...

Page 2: ...ed scanning XY Stage including Mark Find and Autostitching Mosaic Modules Passive anti vibration microscope air table AOBS filter free scanhead WLL2 tuneable pulsed single diode laser with 200 lines f...

Page 3: ...rst Log in with the same WTCHG account on both PCs In the Leica LSM software if you set the WWL to Constant Percent at say 10 the actual laser power will vary depending on the laser line selected If y...

Page 4: ...ectives never change from an oil to an air objective when focussed on the specimen under oil you can start with the low power air objective and then move up to the hi power oil objective The large HC...

Page 5: ...Page 5...

Page 6: ...when looking down the microscope press the diochroic filter selection button e g DAPI and then shutter Also use the fluorescence transmitted light toggle button on the bottom left side of the microsc...

Page 7: ...Page 7...

Page 8: ...Page 8 SmartMove XYZ Stage Controller...

Page 9: ...Page 9...

Page 10: ...ight Red LED rocker switch Note this controls power to the PicaQuant PC and both PC monitors 8 The Leica SP8 Master PC monitor will switch on and this will start up the PicaQuant Slave PC automaticall...

Page 11: ...the SP8 Master PC first 6 Shut Down the SP8 Master PC Transfer any data files to the network drives first 7 Turn the Laser Emission key to off There s no argon laser to cool down and the White Light L...

Page 12: ...e any microscope imaging problems or queries just ask a member of the Microscopy Core staff for help There is additional help and advice on our Core web pages http www well ox ac uk microscopy WTCHG L...

Reviews: