Introduction 

The Leica SP8-X SMD confocal microscope is located in room 00/075, Lab 1. The 
microscope is suitable for both live cell and fixed specimens on slides, and it will 
run alongside the old Zeiss LMS 510 MetaHead confocal.  

The new Leica SP8 has: 

 

An inverted DMI 6000 AFC microscope for live cell viewing 

 

Full live cell chamber with temperature, CO2 and humidity control 

 

SuperZ Galvo Stage and hardware Auto-Focus 

 

10x & 20x HC PL Fluotar air objectives, and 40x & 63x HC PL Apo oil CS2 
objectives 

 

HC PL Apo x63 Mott Corr Water CS2 Objective with software control of the 
correction collar 

 

Transmitted Light Brightfield Detector 

 

Inverted motorised scanning XY Stage including Mark & Find and 
Autostitching/Mosaic Modules 

 

Passive anti-vibration microscope air-table 

 

AOBS filter free scanhead 

 

WLL2 tuneable pulsed single diode laser with 200 lines from 470 to 670nm, 
including Pulse Picker for FLIM (80, 40, 20 10 MHz rep. rate) 

 

405nm Diode Laser for DAPI 

 

Two Internal Spectral Detector Channels (PMT) 

 

Two Internal Spectral Detector Channels (HyD) GaAsP 

 

SMD Excitation: 440nm laser pulsed for FLIM 

 

SMD Emission FLIM+FCS 2Ch HyD Fibre coupled X1 port 

 

SMD Filter Cubes Alexa488/Alexa633 and CFP/YFP, others available 

 

Twin premium Workstations and 30 inch Monitors 

 

Software Modules for all Acquisition modes, 3D, FRAP/FRET/FLIP, Spectral 
Dye Separation, Online Dye Separation, Live Data Mode advanced live cell 
imaging module, Image Processing, Measurement & Reporting 

 

Extra licence for PQ ST Offline Software FCS_FLIM 

 

 

Summary of Contents for SP8-X

Page 1: ...Page 1 Wellcome Trust Centre for Human Genetics Cellular Imaging Microscopy Core The Leica SP8 X SMD Confocal Abridged INSTRUCTIONS...

Page 2: ...ed scanning XY Stage including Mark Find and Autostitching Mosaic Modules Passive anti vibration microscope air table AOBS filter free scanhead WLL2 tuneable pulsed single diode laser with 200 lines f...

Page 3: ...rst Log in with the same WTCHG account on both PCs In the Leica LSM software if you set the WWL to Constant Percent at say 10 the actual laser power will vary depending on the laser line selected If y...

Page 4: ...ectives never change from an oil to an air objective when focussed on the specimen under oil you can start with the low power air objective and then move up to the hi power oil objective The large HC...

Page 5: ...Page 5...

Page 6: ...when looking down the microscope press the diochroic filter selection button e g DAPI and then shutter Also use the fluorescence transmitted light toggle button on the bottom left side of the microsc...

Page 7: ...Page 7...

Page 8: ...Page 8 SmartMove XYZ Stage Controller...

Page 9: ...Page 9...

Page 10: ...ight Red LED rocker switch Note this controls power to the PicaQuant PC and both PC monitors 8 The Leica SP8 Master PC monitor will switch on and this will start up the PicaQuant Slave PC automaticall...

Page 11: ...the SP8 Master PC first 6 Shut Down the SP8 Master PC Transfer any data files to the network drives first 7 Turn the Laser Emission key to off There s no argon laser to cool down and the White Light L...

Page 12: ...e any microscope imaging problems or queries just ask a member of the Microscopy Core staff for help There is additional help and advice on our Core web pages http www well ox ac uk microscopy WTCHG L...

Reviews: