Leica MZ16 A – Operating controls and functions

1

Up/down key for motor zoom and selection in menu

2

Display with function keys

3

Double-iris diaphragm for adjusting the depth of field

4

ErgoTubus™ with variable viewing angle from 10°–50°

5

Adjustable eyepiece tubes for adjusting the interpupillary
distance from 52–76 mm 

6

Knurled rings to adjust diopters from +5 to –5

7

Adjustable eyecups 

8

Manual focusing drive
(or motor focus system, see figure on page 4)
8a Inside coarse drive
8b Outside fine drive
8c Adjustable ring for adjusting ease of movement 

OPT

Selection of eyepiece and objective factors / 

coaxial illumination / acoustic signal

SEL

Confirm and display the selection

CAL

Calibrate motor zoom

REF

Display diameter of reference circle for measurements 

9 Handwheel for precise zooming 

10 Red key: Saving / Traveling / Canceling of stored zoom 

positions 

11 Black key: Toggling between quick and fine 

adjustment

For details and description see the user manual M1-267-1.

Stereomicroscope

Display function keys

Manual control of motor
zoom

Manual control 

motor zoom

Manual control 

motor focus

Summary of Contents for MZ16 A

Page 1: ...Leica MZ16 A User manual ...

Page 2: ...w Components connections 4 Operating controls and functions 6 System operation Starting up 8 Keys 8 Selection OPT 9 Motor zoom control 10 Calibrating the motor zoom 12 Reference circle for measurements 14 Measuring 15 Dimensions 16 Weights 17 Technical data 17 ...

Page 3: ...ems Switzerland Ltd Business unit Stereomicroscopy www stereomicroscopy com Your instrument is supplied with a printed user manual in English Additional languages and information can be found on the interactive CD ROM User manuals and updates are available for download on our homepage at www stereomicroscopy com This user manual describes the special functions of the motor ized Leica MZ16 A stereo...

Page 4: ...Components 4 Leica MZ16 A Overviews Overview 6 1 14 7 8 4 3 2 5 ...

Page 5: ...onnection for motor zoom manual control or empty Supply through power supply of motor focus no other power supply is required 10 PWR empty 14 CTL1 Connection for motor zoom foot switch and or PC interface kit with Y cable 12 CTL2 Connection for motor zoom manual control or empty 13 CTL2 Connection for short connecting cable to motor focus 14 Short connection for motor zoom manual control motor foc...

Page 6: ...6 Leica MZ16 A Operating controls and functions Operating controls and functions 7 3 2 6 5 1 4 8a 8b 8c ...

Page 7: ... figure on page 4 8a Inside coarse drive 8b Outside fine drive 8c Adjustable ring for adjusting ease of movement OPT Selection of eyepiece and objective factors coaxial illumination acoustic signal SEL Confirm and display the selection CAL Calibrate motor zoom REF Display diameter of reference circle for measurements 9 Handwheel for precise zooming 10 Red key Saving Traveling Canceling of stored z...

Page 8: ... initialization concluded 2 beeps Actual magnification Objective 1 0 Eyepiece 10 Coaxial illumination no CAL C dist reference distance REF FOV field of view diameter Acoustic signal on Function 1 Motor zoom up down Function 2 in the Selection Key menu OPTic Select eyepiece and objective factors Coaxial illumination yes no Acoustic signal on off SELect Confirm and display the selection CALibration ...

Page 9: ...stic signal OPT Select eyepiece factor Confirm and display the selection SEL beep Select objective factor Confirm and display the selection SEL beep Coaxial illumination yes no Confirm and display the selection SEL beep Acoustic signal beep on off Confirm and display the selection SEL beep ...

Page 10: ...he user Leaves the hands free Saves time during repetitive tasks A zoom button is located on both sides of the optics carrier Triangle pointing to user Motor zoom up Triangle pointing to stand column Motor zoom down Constant pressure Zoom travels continuously up down Precise fine adjustment with handwheel Short click Motor zoom advances from ratchet step to ratchet step Overall 11 additional ratch...

Page 11: ...tored focus positions Briefly press the red key Cancel the memory position Press the red key until the acoustic signal sounds 2 short beeps pause 2 long beeps Zooming with the foot switch Left hand switch down right hand switch up Toggling between quick and fine adjustment Press left hand and right hand switches simultaneously Zoom positions cannot be stored by means of the footswitch Functionalit...

Page 12: ...ith the handwheel you traveled beyond the adjustable range Delete the preceding calibration see the section on page 13 Travel to desired zoom ratchet step with key 50 0 in the example Initialize calibration with CAL key Select calibration mode with key Magnification C magn or reference distance C dist C magn in the example Confirm and display the selection SEL beep Depending on the selected calibr...

Page 13: ...ndwheel so that the diameter of the small circle inside line corresponds to the distance of 1 40 on the specimen micrometer Confirm and display the calibration 2 CAL beep Display in the example A 50 A Marking of the zoom posi tion used for the calibration Press CAL key at any zoom position Display C dist or C magn depending on the selected mode SEL key Display CD XXX or CM XXX depending on the sel...

Page 14: ...circle C2 or C1 or FOV selected last and the diameter for the current magnification The current magnification returns after 3 seconds Activate the selection menu REF while the current reference circle is displayed Select circle 1 or 2 or FOV field of view Confirm and display the selection SEL beep Display C2 or C1 or FOV and mm or inch or mil depending on the selection Select mm inch or mil Confir...

Page 15: ...ly select Circle 1 or 2 or FOV field of view with Confirm and display the selection SEL beep Display C2 or C1 or FOV and mm or inch or mil depending on the selection Select mm inch or mil Confirm and display the selection SEL beep The current magnification returns after 3 seconds Observe the specimen section to be measured and adjust the magnification with the handwheel so that the specimen sectio...

Page 16: ...16 Leica MZ16 A Dimensions Dimensions of Leica MZ16 A 1 0x Planapo 1 0x Planapo MZ16A MZ16A with incident light stand with transmitted light stand Dimensions in mm ...

Page 17: ...sing drive with column 1 15 kg Technical data of power supply Input voltages 85 V to 264 V 47 Hz to 63 Hz Output voltage 12 VDC Supply connector IEC 320 Low voltage connector Mini DIN 5 pole Operating temperature 10 C to 40 C Relative humidity 85 Storage temperature 20 C to 55 C 17 Leica MZ16 A Technical data Technical data ...

Page 18: ......

Page 19: ......

Page 20: ...ve solutions to our customers needs for vision measurement lithography and analysis of microstructures Leica the leading brand for microscopes and scientific instruments has developed from five brand names all with a long tradition Wild Leitz Reichert Jung and Cambridge Instruments Leica symbolizes not only tradition but also innovation The companies of the Leica Microsystems Group operate interna...

Reviews: