16584_001
1.
Start the PC.
2.
Plug the cable into the instrument.
3.
Turn on the instrument.
4.
Plug the cable into the USB port of the PC.
5.
Press the Windows Start button at the bottom left corner of the
screen.
6.
Type the IP address of the device into the search field.
\\192.168.254.3\
7.
Press
Enter
.
A file browser opens. You can now browse within the folders on the
instrument.
4.8
Guidelines for Correct Results
002410_002
When measurements are being made using the red laser EDM, the results can
be influenced by objects passing between the EDM and the intended target
surface. This occurs because reflectorless measurements are made to the first
surface returning sufficient energy to allow the measurement to take place. For
example, if the intended target surface is the surface of a building, but a vehi-
cle passes between the EDM and the target surface as the measurement is
triggered, the measurement may be made to the side of the vehicle. The result
is the distance to the vehicle, not to the surface of the building.
Very short distances can also be measured reflectorless in Prism mode to well
reflecting natural targets. The distances are corrected with the additive con-
stant defined for the active reflector.
Accurate measurements to prisms should be made in prism mode.
Connect to PC via USB
cable step-by-step
Distance
measurement
☞
☞
42
Operation