iCON grade iCP42, Operation
37
Caution
System Components can protrude from the machine, which could lead to bodily injury and/or
product damage.
Precautions:
Exercise caution in operation to avoid striking any objects or persons near the working area.
3.4.2
Operation with the Tri-Sonic Sensor
iCP42 system flexibility
Multifunctional and multitask - iCP42 system can be operated in various combinations for
the most demanding job requirements.
Mount the Tri-Sonic
Mount the Tri-Sonic to the appropriate height for its maximum performance according to
the reference used. The sensing range shows the minimum and maximum values possible,
wherever it can be achieved to obtain the range of best performance.
Sensing range
Reference
Sensing Range
Best Performance
String
15-36 inch (38-91 cm)
24 inch (60 cm)
Edge
15-36 inch (38-91 cm)
24 inch (60 cm)
Flat Ground
15-99 inch (38-250 cm)
24 inch (60 cm)