background image

15

Leica HI 1210 Water Bath

7.    Warranty and Service

Warranty

Leica Biosystems Nussloch GmbH guarantees that the contractual prod-

uct delivered has been subjected to a comprehensive quality control 

procedure based on the Leica in-house testing standards, and that the 

product is faultless and complies with all technical specifications and/

or characteristics warranted.

The scope of the warranty is based on the content of the concluded 

agreement. The warranty terms of your Leica sales organization or the 

organization from which you have purchased the contractual product 

shall apply exclusively.

Service information

If you require technical service or replacement parts, please contact 

your Leica sales office or dealer who sold the product.
The following inputs are required:
•  Model name and serial number of the instrument.

•  Location of the instrument and name of the person to contact.

•  Reason for the service call.

•  Date of delivery.

Shutdown and disposal of the instrument

The instrument or parts of the instrument must be disposed of in compli-

ance with the local laws.

Special attention should be paid to the lithium cell of the electronic 

 circuit  board!

Summary of Contents for HI1210

Page 1: ...eica HI1210 V 3 4 English 09 2018 Order No 14 0415 80101 RevI Always keep this manual with the instrument Read carefully before working with the instrument Instructions for Use Leica HI1210 Water Bath...

Page 2: ......

Page 3: ...or technical details of the present Instructions for Use are not to be considered warranted characteristics of our products These are determined only by the contract provisions agreed between ourselv...

Page 4: ...ations 9 3 1 Technical data 9 4 Instrument Setup 10 4 1 Location conditions 10 4 2 Standard delivery 10 4 3 Unpacking and setting up the HI1210 11 4 4 Setting up the power supply 11 5 Operation 12 5 1...

Page 5: ...ppear in a gray box and are marked by a warning triangle Observe the instructions for use Manufacturer Notes i e important user information appear in a gray box and are marked by an information symbol...

Page 6: ...Instrument type All information provided in these Instructions for Use applies only to the instrument type indicated on the cover page A nameplate indicating the instrument serial number is attached...

Page 7: ...tion notes in this chapter must be observed at all times Be sure to read these notes even if you are already familiar with the operation and use of other Leica products The protective devices located...

Page 8: ...ervice work During operation the instrument surface can be very hot Risk of injury Do not store any combustible and flammable substances near the instrument The instrument may be operated with non fla...

Page 9: ...For 100 120 V 5x20 mm 2x T 5A L250 VAC For 230 240 V 5x20 mm 2x T 2 5A L250 VAC Dimensions 350x310x100 mm Empty weight 3 6 kg w o packaging Relative humidity 20 80 non condensing IEC 1010 classificati...

Page 10: ...ht and excessive temperature fluctuations The instrument must be connected to a suitable power socket Use only the provided power cable which is intended for the local power supply 4 2 Standard delive...

Page 11: ...f the carton Fig 4 Hold the instrument firmly with one hand pull off both foam sections Fig 5 and remove the dust cover 4 4 Setting up the power supply Before connecting the power cable make sure that...

Page 12: ...ctedtargettempera ture 7 Set key lower temperature 8 Set key increase temperature 9 RUN STOP Switch instrument on or off 10 Display 5 2 Switching the instrument on Before switching the instrument on f...

Page 13: ...to the target value After the desired temperature is reached release the set key The displayed value is saved automatically This stored target value will continue to be displayed for about 2 seconds...

Page 14: ...aboratory detergents The instrument must be switched off and have cooled down for cleaning Do not use organic solvents e g alcohol or xylene 6 2 Replacing fuses Switch the unit off and unplug it Use o...

Page 15: ...ca sales organization or the organization from which you have purchased the contractual product shall apply exclusively Service information If you require technical service or replacement parts please...

Page 16: ...Biosystems com within the product menu This template has to be used for gathering all required data When returning a product a copy of the filled and signed confirmation has to be enclosed or passed o...

Page 17: ......

Page 18: ...www LeicaBiosystems com Leica Biosystems Nussloch GmbH Heidelberger Str 17 19 D 69226 Nussloch Phone 49 0 6224 143 0 Fax 49 0 6224 143 268 Web www LeicaBiosystems com...

Reviews: