5
Regulating the speed:
The rotational sped of the distributor plate can be adjusted in the range 200 – 300
revolutions/min. The value shown in the display is the set value, to which the speed
of the spreading disc is tuned. If as a result of heavy load of the motor or poor electric
supply, the speed of the motor cannot be attained, then on switching the motor on,
the speed actually attained, is displayed. Do not use any other plugs since they often
establish poor contact and have too thin cables; (cigarette lighter, socket – connector
etc.)
Automatic starting:
If starting of the motor becomes difficult on account of the very heavy load, the digital
control starts the motor up to ten times faster. This would give rise to the possibility of
the agitator breaking loose on its own. If this does not work, the motor is switched off.
The message “E 0002” appears on the display. The spreader must be switched off
and rotated manually. Attention - risk of injury!
Error control:
Indication on the display:
possible cause:
E001 set position slider motor/
mechanically clamped
Error Description: Adjusted
Power supply interrupted
Slider position not attained.
Motor defective
Control defective
E002 blocking drive motor
Agitator blocked by foreign bodies
Error Description: Motor does
(Vessel empty and inspect)
not rotate and will be shut down Power supply interrupted
after ten attempts to start.
Motor defective
Control defective
E003 error reference run of the slider -
mechanically jammed
Motor Error Description: Slider
Wiring defective
does not attain the positions open / closed Motor defective
during the reference run.
Check the Slider unit and clean if necessary. Control defective
Repeat the reference run. +/- Key
Press simultaneously.