The following steps must be observed when the error message
Slide
not open
or
Slide not closed
appears in the display.
1. Switch off the control console.
2. Wait 15-20 seconds.
3. Switch on the control console.
The slide automatically opens/closes by approx. 10 mm. This allows the
foreign body to be removed. If this is not the case, the foreign body must
be removed manually.
4. Wait 15-20 seconds.
5. Switch off the control console.
6. Switch on the control console.
The slide closes automatically and the 0 position is reached.
Important note:
Once the blockage has been successfully removed, before refilling
the hopper, ensure that the slide is in the 0 position (is fully closed).
Check by taking a quick look inside the hopper.
3.7 Setting the working width
The spreading width depends on the condition of the spreading material
and the speed of the spreading disc. The more coarse the spreading
material, the larger the possible spreading width.
1. Set the speed according to the spreading chart.
2. Set the casting blades according to the spreading chart.