OVERVIEW OF TRANSPONDER CARDS

As user cards, you can either use LEHMANN user cards or cards of a third-party provider complying with ISO 14443A. 
Please note the following possible restrictions when using user cards of third-party providers:

 

•  The comprehensive security concept, which was specially designed for this locking system in conjunction  

with the user cards of LEHMANN Vertriebsgesellschaft mbH & Co. KG, may be affected by the use of  
user cards of a third-party provider.

 

•  The “Shared use“ operating mode is only possible with user cards from third-party providers if they have  

the appropriate write permission for the user card.

 

• Transponder cards with a so-called “Random-UID“ are not supported. 

For the highest possible level of safety, transponder cards based on MIFARE® DESFire are recommended. 
Please note that installation cards, master cards, user cards and programming cards must be ordered separately.

Please keep the master and update cards as well as the card with the individual service key carefully and securely!
 
 

Card type                  

Description

Installation card  
(only for assembly  
and testing purposes)

The installation card can be used specially for assembly and testing purposes in order to 
perform basic functions on the lock (opening and closing). Furthermore, the lock can be closed 
using the installation card for transporting the furniture to its destination. This card is for 
universal use. Any number of installation cards can be used at any lock. Prior programming of a 
master card is not necessary. After a master card has been programmed for the first time, the 
lock is disabled for the installation card. The use of an installation card is optional.

Master card 

For complete commissioning, a master card must be programmed for both operating modes. 
The master card is required for starting and terminating programming operations. This also 
includes the programming of user cards in “Assigned use“ mode. The master card also enables 
the so-called Facility Manager function and the emergency opening of the lock. A maximum of 
one master card can be programmed per lock. You can use one master card for several locks.

User card 

User cards are used to open and close the lock. In “Assigned use“ mode, up to 50 user cards 
can be programmed on one lock. In “Shared use“ mode, one user card can be used temporarily 
on one lock. It is possible to program one user card on several locks in “Assigned use“ mode, 
and at the same time on one lock in “Shared use“ mode.

Programming card set 

For certain programming functions, programming cards are required in conjunction with the 
master card. The programming card set consists of 3 universal programming cards:
• P1: Mode (change of mode)
• P2: Sound (activating or deactivating acoustic signals)
• P3: Reset (reset to factory settings)

Update card 

In addition to the master card, you will receive an update card. In conjunction with the master 
card, the update card allows firmware updates to be loaded into this locking system

Service key 

In addition to the master card and update card, you will receive a card with an individual 
service key. Please keep the card with the service key carefully and securely. The printed service 
key allows you to reorder master and update cards. It is not possible to reorder a master card 
or an update card without a service key! This card has no electronic function!

Summary of Contents for M410 L033-A01

Page 1: ...rd Programming the master card 9 Programming the user cards Closing opening 10 Unauthorised transponder cards Facility Manager function Emergency opening 11 Deleting individual transponder cards Deleting all transponder cards 12 Changing the operating mode 13 Deactivating and activating acoustic signals Resetting to factory settings 14 Battery warning 15 External power supply Firmware update 16 Re...

Page 2: ...as the scope of items in the system are subject to change without notice CAUTION Please keep the master and update cards as well as the card with the individual service key carefully and securely TECHNICAL SPECIFICATIONS SAFETY PRECAUTIONS U U When replacing the battery make sure that the polarity and position of the battery is correct U U Dispose of used batteries properly U U Do not heat batteri...

Page 3: ...ting modes are available Only the M410 L033 A02 with a spacer is suitable for use on metallic surfaces Please note that the distance between two or more RFID readers must be at least 5 cm This system is not intended for push to open applications If required this needs to be tested on individual basis Lock operating mode Description Assigned use factory settings There is a fixed assignment between ...

Page 4: ...ogrammed for the first time the lock is disabled for the installation card The use of an installation card is optional Master card For complete commissioning a master card must be programmed for both operating modes The master card is required for starting and terminating programming operations This also includes the programming of user cards in Assigned use mode The master card also enables the s...

Page 5: ...5x35 for M410 3 1x battery CR123A 4 Striker plate 5 3x screw 3x13 for striker plate 6 Cable Optional components for RFID reader L033 A01 7 RFID reader L033 A01 8 2x thermoplastic screw 3x20 9 RFID reader housing for internal mounting 10 2x screw 3x13 for RFID reader housing 11 Double sided adhesive tape Optional components for RFID reader L033 A02 12 RFID reader L033 A02 13 2x thermoplastic screw ...

Page 6: ...sible with an external RFID reader Please note the different mounting positions and drilling pattern for the RFID readers RFID reader L033 A01 RFID reader L033 A02 without spacer RFID reader L033 A02 with spacer CAUTION For mounting the RFID reader L033 A02 without spacer please use drill holes of 5 5mm with spacer please use drill holes of 3 5mm Please countersink holes for screwheads Tighten the...

Page 7: ...sing screws by hand and then connect the optical cable to the lock 5 Remove the protective film from the rear side of the adhesive tape Then stick the entire reading unit to the inner side of the door Please position the RFID reader in such a way that you still have access to the micro USB port DIMENSIONS 4 5 1 2 3 RFID reader L033 A01 64 7 25 5 5 2 Ø 40 73 RFID reader L033 A02 RFID reader L033 A0...

Page 8: ...R THE FOLLOWING PROGRAMMING STEPS The last 5 seconds before the shutdown of the programming process are announced by the flashing of a yellow lamp and acoustic signals The visual and acoustic signals are differentiated as follows Optical signals Short flashing Long flashing Acoustic signals Short Long Inserting the battery Battery is inserted correctly in the battery compartment Open the battery c...

Page 9: ...ROGRAMMING THE MASTER CARD Irrespective of the desired operating mode a master card must always be programmed before further programming and operation Only one master card can be programmed per lock The programming of the master card can be carried out when the lock is closed as well as when it is open If the lock is closed after the master card has been programmed the next step must be an emergen...

Page 10: ...e user cards see Closing and Opening P 10 After programming the user cards can open and close the lock Programming user cards Master Hold the master card in front of the reader User Hold the user card in front of the reader The card is accepted and programmed This process can be repeated to program multiple user cards Card is not accepted Master Hold the master card in front of the reader CLOSING ...

Page 11: ...unction the lock opens for 30 seconds and then closes automatically After this automatic closure authorised user cards can continue to be used in Shared use mode as well as in Assigned use mode EMERGENCY OPENING In the event that one or all authorised user cards are currently not available an emergency opening can be effected with the master card Please note that the lock remains open after emerge...

Page 12: ...aster Hold the master card in front of the reader User Hold the user card to be deleted in front of the reader Master Hold the master card in front of the reader DELETING ALL TRANSPONDER CARDS only for Assigned use mode The deleting process can only be carried out when the lock is open Should there be no authorised user card to hand first perform an emergency opening using the master card Deleting...

Page 13: ...t separately from LEHMANN Vertriebs gesellschaft mbH Co KG The cards are for universal use Changing the operating mode Master Hold the master card in front of the reader P1 Mode Hold the programming card No 1 P1 Mode in front of the reader Shared use mode is selected Shared use P1 Mode Hold the programming card No 1 P1 Mode in front of the reader again Assigned use mode is selected Assigned use Ma...

Page 14: ...t mbH Co KG The cards are for universal use Deactivating and activating acoustic signals Master Hold the master card in front of the reader P2 Sound Hold the programming card No 2 P2 Sound in front of the reader The acoustic signals are deactivated Acoustic signals are deactivated P2 Sound Hold the programming card No 2 P2 Sound in front of the reader again Acoustic signals are activated again Aco...

Page 15: ...acement in the event of reduced battery power The battery warning takes place in two phases The settings are saved even without a power supply e g in case of battery replacement or in case the battery should be completely empty Battery replacement should be carried out within 5 minutes Battery warning Phase 1 Before an action can be carried out closing opening programming a battery warning is give...

Page 16: ...ding the charging process U U Please do not perform any further actions until the RFID reader gives an acoustic and a visual signal see Acoustic and visual signals when inserting the battery U U Then open the lock with an authorised transponder card Here you can use either a programmed user card or the master card for emergency opening U U Then carefully disconnect the power bank from the RFID rea...

Page 17: ...d the number of replacement cards you require Transponder card cannot be programmed Possible reasons Storage space is used up Card is not compatible Master card has not yet been programmed Available storage space in the lock is used up Possible reasons 50 user cards have already been programmed in the lock Bolt warning the bolt does not move to the end position Possible reasons Striker plate or lo...

Page 18: ...ck the functions open close with an authorised user card again when the furniture is open If the lock should work properly please check to see if the bolt can extend correctly when the furniture is closed see installation recommendation If you are using an existing user card not from the Lehmann company check to see whether the appropriate write permission has been given for the transponder card L...

Page 19: ...BDA M410 L033 A01 A02 2018 04 24 GB 19 NOTES ...

Page 20: ...A01 A02 2018 04 24 GB 20 LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2008 zertifiziert ...

Reviews: