12
PUB 751-0012
Rev. C—1/12/2012
17.
See Fig. 14
. Install black extension wire to
black wire from top tour box harness with red
Posi-lock tap. Connect eyelet connector to
negative terminal of battery.
18.
See Fig. 15
. Install red extension wire to red
wire from tour box harness with in-line fuse cap.
Connect eyelet connector to positive terminal of
battery.
19. Insert 3-amp fuse in fuse receptacle.
20. Turn on power and test tour box lighting and
remote.
21. Using electrical tape, cover exposed wires on
body wiring harness where heat shrink was re-
moved.
NOTE: See Fig. 16. Before securing tour
box wiring harness with cable ties, adjust
tour box wiring harness sheath to ensure
coverage of exposed wires coming from bot-
tom of tour box base. Also, be sure harness
isn’t positioned to get pinched by operator
seat when re-installed.
TOUR BOX INSTALLATION CONTINUED
Fig. 14
Fig. 15
Fig. 16
2. Connect eyelet to negative terminal
1. Connect red cap to black wire of
tour box wiring harness.
2. Connect eyelet to positive terminal
1. Connect in-line fuse cap to red
wire of tour box wiring harness.
Red
Adjust sheath to
ensure wires are
not exposed