Smoke Alarm 
869MHz

 

Caring for People 

 
 

 

 
_________________________________________________________________________

 

________________________________________________________________ 

 
 

 
 

 

 

  Doc No. FM0822 V1.02 Page 1   

 

 

 

 

 

 

 
 
 

 

Compatible with Reach IP and Advent XT2 

 

Complies with EN 14604-2005+AC:2008 

 

Thermoptek multi-sensor technology 

 

10 year sealed for life Lithium battery (typical) 

 

Alarm sound level: 85dB @ 3m 

 

Large central Test/Silence (

) button 

 

Operating Temperature: +4

o

C to +38

o

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat 

 

Weight: 210 grams 

 

Dimensions: 132mm diameter x 40.5mm depth 

 

Product Code: ZXT810

 

 

Positioning

 

Smoke alarms should be sited at least 300mm from light fittings 
and walls, ideally as centrally as possible in the room. Smoke 
alarms should be positioned no more than 600mm below the 
highest point in the room. If positioning on the wall, the top of 
the smoke alarm must be between 150mm and 300mm below 
the ceiling and at least 300mm from a wall. 
Thermoptek smoke alarms are less prone to false alarms from 
cooking fumes and are therefore suitable for locating near 
kitchens. Like other smoke alarms they can be susceptible to 
nuisance alarms from steam and should not be placed near 
bathrooms. 

Refer to the Manufacturer’s 

instruction booklet for 

more information on positioning. 

 

Normal Operation

 

The red light will flash once every 45 seconds to indicate normal 
operation. 

 

Alarm Condition

 

The unit will repeatedly sound 3 loud beeps and the red light will 
flash every second. Check if there is a fire hazard and 

leave the 

building immediately.

  

DANGER:

 

Never ignore any alarm. If you are not certain of the 

cause, leave the building immediately. 

 

Alarm Silence

 

In the event of a known false alarm you can temporarily silence 
the smoke alarm by pressing the Test/

 button. The alarm will 

automatically return to full sensitivity after 10 minutes.  

NOTE:

 If the level of smoke is very high the alarm silence will be 

overridden, and the alarm will continue to sound. 

Low Battery Condition

 

If the unit chirps every 45 seconds and the yellow light flashes at 
the same time, this indicates the battery is running low. The low 
battery condition will be reported automatically to the Alarm 
Receiving Centre (ARC) or the local Manager.  
The smoke alarm should be replaced within 30 days. 

 

Sleep Easy Feature 

Low battery warnings often start at night or when it may be 
inconvenient to replace the alarm. You can silence the audible 
low battery chirp for a period of eight hours by pressing the  
Test/

 button. After this period the audible chirp will start 

again. This process can be repeated up to 10 times. The alarm  
will still detect smoke during this time, however it must be 
replaced within 30 days.  

 

Fault Condition

 

If the unit chirps every 45 seconds and the yellow light flashes  
20-25 seconds after, this indicates a fault with the smoke alarm 
and it should be replaced immediately. 

 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed from 

an installation. Should the Reach IP be unable to detect a device’s 

heartbeat it will 

automatically generate a “radio out of range” 

notification. Firstly, investigate if there’s a genuine reason for the 

alert, if not, arrange for the peripheral device to be replaced 
immediately. 

The “Radio out of range timer” can be set from 30 

hours to 999

99 hours in Pulse CMP. “Radio supervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the smoke alarm once every week. 
Clean once every 3 months using a vacuum cleaner fitted with 
the soft brush attachment. Do not use solvents or cleaners on the 
smoke alarm as they may cause damage to the sensor, the unit 
can be wiped with a damp cloth. 
Do not paint the smoke alarm as this may block the vents and 
prevent smoke from entering the sensor. 

 

Disposal

 

Waste electrical products should not be disposed of with normal 
household waste. The smoke alarm is ideally suited for disposal 
within the waste electronic and electrical equipment (WEEE) 
recycling scheme. Please recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 

 

Warning

 

The smoke alarm contains a powerful Lithium battery.  
If tampered with the battery may be damaged and create a fire 
hazard. No attempt should be made to open the case or remove 
the battery. Do not incinerate.

 

 

 