The battery power will 
now be switched on and 
the red light will flash 
once every 45 seconds to 
show that it is active. 

The unit will sound an 
audible alarm consisting 
of 2 cycles of 3 loud 
beeps, then stop 
automatically. 

ZXT810

 

S:081923608  
Iss-2 

15930800D3

   

19W8

 

The Radio ID is a 10-digit code 
printed on the radio module 
label on the back of the 
smoke alarm

  

How to install the Smoke Alarm

 

Make sure you have read and understood the instructions on 
positioning the alarm before starting. 

 

The base plate must be securely fixed to the ceiling or wall.  
Use the fixing slots on the base plate as a guide when marking 
the position of the drill holes. Fix with the screws and plugs 
provided.  

 

Alternatively, the base plate can be fixed with the self-adhesive 
pads provided. Ensure the surface is smooth, clean and dry. 
Press hard to make sure the pads are properly adhered. 

 

 

Position the alarm on the base plate then twist it clockwise until 
the alarm is fully locked in position.  

 

 

 

 

 

WARNING:

 

Removing the alarm from its base plate will  

de-activate the unit and prevent it from detecting smoke. 
  

How to test the Smoke Alarm

  

Press the Test/

 button in the centre and release.  

 

 

 

 

 

The red light on the alarm will flash rapidly during the audible 
signal. 
 

Telecare Radio ID

 

The smoke alarm includes a plug-in radio transceiver module to 
communicate with the Reach IP or Advent XT2. 

 

 

 

 
 

 

 

 

Registering the Smoke Alarm onto a Reach IP

 

Login to Pulse CMP (www.tynetecpulse.com) and enter the  
Reach IP Serial No. in the 

ALARM UNIT

 view.  

Press the 

Accessories

 button and enter the Radio ID code, 

Location and Equipment type. Press 

Save

 then 

 

Synchronize

IMPORTANT

: when the smoke alarm is installed a test call must 

be made to check operation and start the digital heartbeat. 

 

Alternatively, with the Reach IP in normal operating mode undo 
the fixing screw and remove the stand or connector cover to 
access the 

 Power button.

 

 

 

Press the 

 Power button to enter Control Mode, then press and 

hold the 

 button 

until the unit announces “

add radio device

” 

then release.  
Press the 

 button to confirm then activate the smoke alarm by 

pressing the Test button.  

The Reach IP unit will sound a high beep if it’s a new device and 
announce “

range test mode

.  

Press 

 to confirm, or press 

 to step to the next function, or 

press 

 to exit the mode. 

 

 

Registering the Smoke Alarm onto an Advent XT2

 

Radio device programming can only be performed from the 

Advent XT2 Manager’s Panel designated as the 

Controller

.  

Login using the Manager or Engineer password and touch the 
Programming button.  
Select the 

Program Radio Devices

 option from the Program 

Setting drop-down list.

 

 

 
 
 
 
 
 
 
 
 
 

Enter the 

Radio ID: 

this is the 10-digit code taken from the radio 

module label on the back of the smoke alarm. 
Enter the 

Flat ID: 

this is the flat number the smoke alarm is being 

installed in. Enter 4-digits e.g. 0014. 
Enter the 

Location: 

select where the smoke alarm is

 

located from 

the drop-down list e.g. Living Room. 
Press the 

Send

 button to update the XT2 system. 

Press the test button on the smoke alarm to check operation. 