Smoke Alarm
869MHz
Caring for People
_________________________________________________________________________
________________________________________________________________
Doc No. FM0822 V1.02 Page 2
The battery power will
now be switched on and
the red light will flash
once every 45 seconds to
show that it is active.
The unit will sound an
audible alarm consisting
of 2 cycles of 3 loud
beeps, then stop
automatically.
ZXT810
S:081923608
Iss-2
15930800D3
19W8
The Radio ID is a 10-digit code
printed on the radio module
label on the back of the
smoke alarm
…
How to install the Smoke Alarm
Make sure you have read and understood the instructions on
positioning the alarm before starting.
The base plate must be securely fixed to the ceiling or wall.
Use the fixing slots on the base plate as a guide when marking
the position of the drill holes. Fix with the screws and plugs
provided.
Alternatively, the base plate can be fixed with the self-adhesive
pads provided. Ensure the surface is smooth, clean and dry.
Press hard to make sure the pads are properly adhered.
Position the alarm on the base plate then twist it clockwise until
the alarm is fully locked in position.
WARNING:
Removing the alarm from its base plate will
de-activate the unit and prevent it from detecting smoke.
How to test the Smoke Alarm
Press the Test/
button in the centre and release.
The red light on the alarm will flash rapidly during the audible
signal.
Telecare Radio ID
The smoke alarm includes a plug-in radio transceiver module to
communicate with the Reach IP or Advent XT2.
Registering the Smoke Alarm onto a Reach IP
Login to Pulse CMP (www.tynetecpulse.com) and enter the
Reach IP Serial No. in the
ALARM UNIT
view.
Press the
Accessories
button and enter the Radio ID code,
Location and Equipment type. Press
Save
then
Synchronize
.
IMPORTANT
: when the smoke alarm is installed a test call must
be made to check operation and start the digital heartbeat.
Alternatively, with the Reach IP in normal operating mode undo
the fixing screw and remove the stand or connector cover to
access the
⚫
Power button.
Press the
⚫
Power button to enter Control Mode, then press and
hold the
button
until the unit announces “
add radio device
”
then release.
Press the
⚫
button to confirm then activate the smoke alarm by
pressing the Test button.
The Reach IP unit will sound a high beep if it’s a new device and
announce “
range test mode
”
.
Press
⚫
to confirm, or press
to step to the next function, or
press
to exit the mode.
Registering the Smoke Alarm onto an Advent XT2
Radio device programming can only be performed from the
Advent XT2 Manager’s Panel designated as the
Controller
.
Login using the Manager or Engineer password and touch the
Programming button.
Select the
Program Radio Devices
option from the Program
Setting drop-down list.
Enter the
Radio ID:
this is the 10-digit code taken from the radio
module label on the back of the smoke alarm.
Enter the
Flat ID:
this is the flat number the smoke alarm is being
installed in. Enter 4-digits e.g. 0014.
Enter the
Location:
select where the smoke alarm is
located from
the drop-down list e.g. Living Room.
Press the
Send
button to update the XT2 system.
Press the test button on the smoke alarm to check operation.
⚫
Power Button