Doc No. FM0410 issue N Page 45
32. ETHERNET INTERFACE KIT INSTALLATION
The optional Ethernet Interface Kit stores all alarm and Telecare data with the time and date of each event on a local
Memory Card. The stored data can be downloaded and analysed using Tynetec’s
I-Care software. There are 3 generations
of interface kits as the Rabbitcore Module/Memory Card has changed over the years.
ZXT120 KIT (MK1)
ZXT121 KIT (MK2)
ZXT122 KIT (MK3)
A00382 Expander
A00382 Expander
A00382 Expander
RCM3365 Rabbitcore Module
RCM3900 Rabbitcore Module
RCM3900 Rabbitcore Module
128MB XD Memory Card
1GB
Mini
SD Memory Card
1GB
Micro
SD Memory Card
RJ45 Crossover Lead
RJ45 Crossover Lead
RJ45 Crossover Lead
Any of the above kits can be used with Advent xt Controller V1.05 firmware onwards. V1.05 only stores alarm calls and
PIR activity, with V2.0 onwards all Telecare and Telehealth data is also stored. The ZXT121 or ZXT122 kit is recommended
for V2.0 as it has almost 8 times the memory capacity of the ZXT120 for the increased volume of data stored on the card.
LOCAL/REMOTE CONNECTION
A 2 metre RJ45 Crossover Lead is provided for direct connection to a local PC - this can be extended up 100 metres using
CAT5e cable and RJ45 outlet sockets.
A standard RJ45 Patch Lead (not supplied) and Broadband with a fixed IP address is required for remote connection.
INSTALLATION
The Ethernet Interface Kit will normally be factory fitted, however it can be fitted on site as an upgrade.
Turn the mains supply off the Advent xt controller and disconnect the standby batteries before starting.
IMPORTANT: always observe anti-static precautions when working on the controller motherboard.
Remove the lid and clear perspex cover from the Advent xt controller, plug the A00382 Expander Board into the sockets
JP5 & JP6 on the A00380 motherboard. Plug the Memory Card and RJ45 lead into the Rabbitcore Module then refit the
cover and power-up the controller.
PROGRAMMING
The Advent xt controller requires no special programming; however the Rabbitcore Module must be set-up using the
manual provided (Doc No. FM0552).