25. DIGITAL DOOR PANEL INSTALLATION
TERMINATION
See Tynetec Drg No. ZXT100 sheet 3 for detailed wiring connections;
DOOR PANEL AMPLIFIER BOARD
LINK SETTINGS
LK1 selects a standard or fail safe lock type; a standard lock requires power to unlock (fail-secure) whereas a fail-safe lock
requires power to lock (fail open). See below for other link settings.
Link No.
Link Position “A
”
Link Position “B”
A0436B - LK1
fit for fail-secure lock
fit for fail-safe lock
A0436B - LK2
no expander fitted
expander board fitted
A0436B - LK3
A00418 type expander
A00437 type expander
A0436B - LK4
normal
not used for Advent xt
A00418 - LK4
normal
no speech and no tones
The lock release duration is set in the “Door Entry Setup”
programming; see the Advent xt Programming Manual (Tynetec
Doc No. FM0411).
8 WAY DIL SWITCH SETTINGS
(SW2)
DIL switches 1 to 4 are used to set a unique door panel ID (1 to 16). Door panel ID’s must start from 1 and run
sequentially. DIL switches 5 to 8 select the door panel features should all be ON for Advent xt.
DIL SW
Door Panel ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
5
ON
for Digital Door Panel - OFF for Functional Door Panel
6
OFF
A-F Button
(Normal)
ON
Concierge
Button
OFF
A-F & Concierge
Button
ON
Advent XT Manager
Button
7
OFF
OFF
ON
ON
8
OFF = No Expander -
ON
= Expander Board Fitted
4 WAY DIL SWITCH SETTINGS
(SW1)
DIL switches 1 to 4 are normally all OFF. Set DIL Switch 1 ON to disable the voice reassurance and revert to standard
reassurance tones. DIL switches 3 to 4 have no function.
Terminal
Function
Connection
IP 1
Play Welcome Message
0V Trigger
IP 2
No Function
Not Connected
RELAY
Activates for duration of call
Not Connected
SP1
Warden Call Loudspeaker Audio
1 pair CW1308 to
Advent xt Controller
SP2
Mic
Warden Call Microphone Audio
1 wire CW1308 to
Advent xt Controller
12V
12V DC Supply for Door Panel
2 pairs CW1308 to
Advent xt Controller
0V
0V Supply for Door Panel
TX+
RS485 Data +
1 pair CW1308 to
Advent xt Controller
TX-
RS485 Data -
C1
Door Entry Audio to Door
1 pair CW1308 to
Advent xt Controller
C2
Door Entry Audio to Phone
CONC
Concierge Call output
Not Connected
T/G
Tailgate input (N/C)
2 pairs CW1308 to
PTE & Door Contact
EXLK
External Lock input (N/O)
0V
Common for T/G & EXLK inputs
LKSP
Lock Supply Voltage
1.0 mm pair to
Door Lock
LKRT
Lock Return Voltage
+
Lock Power 12V
1.0 mm pair to local
Lock PSU
-
Lock Power Supply 0V