(N)

Neutral

(Blue)

Live

(Black)

Output
(Brown)

(L)

(Orange)

(OUT)

Master
(Red)

(M)

Switch off the power source before installation & maintenance

Warning!

Installation:

Step 1: 

Identify the location and direction of any hidden supply cables or service pipes before 

drilling fixing holes.

Step 2: 

Mark and drill mounting holes for the snap-in ceiling clips at the correct spacing  (Fig.1).

Step 3: 

Fix the clips securely to the ceiling (A).

Remote Control Setup:

● Pull plastic protection from battery compartment to activate the remote control.
● The factory settings by default are: 
   ○ Range (sensitivity) 10 metres distance.
   ○ Time ( the time the fitting will stay on for) is 10 seconds.
   ○ (The light sensitivity) By default the sensor will function all day and night (2000Lux).

 

● Changing the default settings:
   ○ Point the remote towards the fitting within 10m metres and press the AUTO button.
   ○ Select the mode of adjustment required, eg, sensitivity (range). Press the required range be 
      it 2m, 4m, 10m etc.
   ○ The light will then flash once acknowledging the new setting.
   ○ Repeat the same for all other adjustments required (stand-by time, lux).  

Remote Control Functions:

(Fig.1)

58mm

100mm

24mm

Range Adjustment 

MAX detection distance 14-15m
10m detection distance 
8m detection distance 
6m detection distance 
4m detection distance 
2m detection distance 

Light ON/OFF 

ON - Manual ON switch
OFF - Manual OFF switch
overriding the sensor.
(sensor disabled in this mode)
After 6 hours the sensor goes
back into "AUTO" mode.

AUTO Mode

The sensor starts to work 
automatically and all settings 
remain the same as the latest 
status before pushing ON/OFF 
button, Test or Reset button.

Resets all functions

Default settings:

 10m range 

 10 sec. 

 2000lux - Daylight mode 

Time Adjustment

Min: 10 Sec.
Max: 60 Min.

Lux Level Adjustment

Set daylights threshold from
10lux to 2000lux.   
For daylight mode use 500lux
to 2000lux settings.

Lux Level Overwrite

Sets the surrounding lux value as
the daylight threshold (overwrites
the existing lux values).
Allows the fitting to function in any
desired light circumstances.

Permanent Lock Mode

Permanent inhibition of the 
sensor - light permanent ON/OFF.
Only the ON and OFF functions 
on the remote are available.
Press button again to exit mode.

Installation*

*Can also be suspended with traditional hooks & Jack chain. Not supplied.

The fitting comes with both waterproof cable 
glands installed, one side has a silicone cover
to ensure the IP65 rating. In order to utilize 
both connections, remove the blanking plate 
by unscrewing the cover.

N

L

NEXT LIGHT

LIGHT FITTING

(N)

(L)

Neutral

(Blue)

Live

(Brown)

Step 4: 

Using a screw loosen and open the cover for the connection Block 1 and wire the main

input to the terminal block of the light fitting (B). The fitting comes pre-wired as a standard single 
fitting (Fig.2) with a link between Live(L) and Output (OUT) connections and it can be wired as 
a Master to Slave sensor fitting by connecting the Orange wire from Master (M) to the 
Output (OUT) connection (Fig.3). Connection Block 2 is used for output only (Fig. 4). 
For detailed wiring see the instructions below.

Step 5: 

Close the connection box cover (C) on the connection Block 1 and mount the light fitting 

onto the metal clips ensuring that it is secured into place (D).

Step 6: 

Power up the fitting to check that it functions correctly (E).

(Fig.4)

(Fig.2)

Wiring Instructions:

POWER SUPPLY

LIGHT FITTING

POWER SUPPLY

LIGHT FITTING

(Fig.3)

(N)

Neutral

(Blue)

Live

(Black)

Output
(Brown)

(L)

(Orange)

(OUT)

Master
(Red)

(M)

1(Input)

2(Output)

Connection Block 2 (Output)

Connection Block 1(Input)

Standard Wiring

Connection Block 1(Input)

Master to Slave Wiring

● 

ON/OFF Mode

   ○ When ON/OFF buttons are pressed the light is turned ON/OFF overriding the
      sensor. The Batten fitting will enter AUTO mode after 6 hours.
   ○ To exit ON/OFF Mode press AUTO button.

● 

LOCK/UNLOCK Mode

   ○ When       is pressed the remote control is locked, only ON and OFF functions on the remote are 
      available. 
   ○ Push the        button again to unlock the remote control. 

Operation Modes:

Test Mode

Hold the button for 2 seconds to
enter test mode. Time and lux
level are disabled in Test Mode.
Press Auto button to exit Test 
Mode.