Page 46 of 52
54A0025-5 102018 © LeddarTech Inc.
5.6. Regulatory Compliance
Table 17: Regulatory Compliance
Test Name
Standards
Test Specifications
Performance
Criterion
Results
Radiated Emissions
FCC part 15 (2013) subpart B
Class A
30 MHz-1 GHz
N/A
Pass
Radiated Emissions
CISPR11 (2009) A1 (2010)
Group 1 - class A
30 MHz-1 GHz
N/A
Pass
Radiated Emissions
ICES-003 (2012)
Class A
30 MHz-1 GHz
N/A
Pass
Electrostatic Discharge Immunity
IEC61000-4-2 (2008)
Contact: ±4 kV
Air: ±8 kV
B
Pass
Radiated Electromagnetic Field
Immunity
IEC61000-4-3 (2006)
A1 (2007) A2 (2010)
80 MHz-1000 MHz: 10 V/m
1.4 GHz-2 GHz: 3 V/m
2 GHz-2.7 GHz : 1 V/m
A
Pass
Power Frequency Magnetic Field
Immunity
IEC61000-4-8 (2009)
Continuous Field: 30A/m / 50 Hz &
60 Hz
A
Pass
Note: Testing results are valid for cable length less than 3 meters.