9
Enter, Adjust and Exit Program Mode:
•
Before entering program mode, 12vdc or 24vdc must be applied to MLC
terminals 1, 2 and 7 (see wiring)
•
Press and hold Bow Down (top) button and Bow Up (bottom) button for 4
seconds to enter program mode
•
LED L1 (top left LED) will begin flashing and LED R1 (top right LED) will be lit
constantly
•
Press and release the Port Side Down (left) button to cycle through the three
settings under “Setting”
•
Press and release the Starboard Side Down (right) button to chang
e the “Setting
Value”
•
Press and hold Bow Down (top) button and Bow Up (bottom) button for 4
seconds to exit and save new value
Program Mode Sequence
Setting
Enter
Change Setting
Change Setting
Value
Setting Value
Default
Program Details
(1L) Auto
Retract
Last
Setting
Press Bow
Down and Bow
Up 4 sec.
Press/Release
Port Bow Side
Down
Press/Release
Stbd Bow
Down
R1 = Standard
R2 = Last Tab
Set
R1
R1=Standard Auto Retract
R2=Return to last tab position
before key switch off
(2L)
Actuator
Stroke
Time
Press Bow
Down and Bow
Up 4 sec.
Press/Release
Port Bow Side
Down
Press/Release
Stbd Bow
Down
R1=4sec,
R2=5sec.,
R3=6s, R4=7s,
R5=8s
R5
Change setting value to match
actuator stroke time to fully
deploy
(3L) Swap
LED
tracking
Press Bow
Down and Bow
Up 4 sec.
Press/Release
Port Bow Side
Down
Press/Release
Stbd Bow
Down
R1 = LEDs
track tab
position
R2 = LEDs
track button
press
R1
R1==LEDs track angle of tab
position
R2=LEDs track same side as
button being pressed
Summary of Contents for MLC-1
Page 11: ...11...