3
0
Clamp one nozzle 5TM.0XX.1Y.23.YS.0 (pos. 21) in the vice and loosen the
5TC.0001Y.24.C0.0 connecting piece (pos. 22) with a face wrench (bolt diameter 5.0 mm).
Remove bevel gear 5TC.000.1Y.22.00.0 (pos. 20).
Remove upper bearing ring 5TC.000.C9.26.R0.0 ( pos. 26), ball bearing