background image

C. Testing the WaterComm device

Ensure the lithium ER26500 battery is installed.

Test the device in its intended position to ensure that it connects to the IoT network.

Simulate a leak by plugging a connecting cable into port 1 of the device and holding the two male test 
pins together for 20 seconds then release the pins.

The Port 1 red LED will illuminate, and the small green and blue LED indicators on either side of the 
central blue On/Off button will flash to indicate that it is transmitting a leak alarm.

Check that you receive a SMS (or email).

Disconnect the cable.

E.  Installation method: WaterComm device

Mount the WaterComm device in the desired location using the supplied backplate.

Plug the leak detection tape(s) and connecting cable(s) into the allocated ports on the WaterComm device.

D. Installation method: leak detection tapes

Leaksafe leak detection tapes are supplied in standard lengths of 1M or 2M and can be daisy chained 
together if longer lengths are required. 

If the system is being used as a centrally located panel, then the connecting cable can be extended 
using either 2 wire 13 core audio cable or YY 0.05mm

2

 cable. No more than 25M of cable and tape can 

be connected in a single length.

To daisy chain lengths of leak detection tape, push the male & female connectors at the end of the 
tapes together and crimp using a crimp tool. 

Connect the length of tape to the connecting cable by inserting the male connectors to the female 
connectors at the end of the tape and crimp the connection.

Position the tape as required. Tape should be laid under pipe joints and connections. The tape can be 
laid directly on a floor or surface with or without retaining clips depending on the location of the tape 
and whether it is likely to be disturbed. 

Tape can also be contained within pre-drilled mini trunking if appropriate, ensuring that there are 
sufficient holes of adequate size so that if a leak does occur, the water would quickly soak into the leak 
detection tape.

LEAK

SAFE

 SOLUTIONS | WATERCOMM INSTALLATION GUIDE

PAGE 3

Summary of Contents for WaterComm

Page 1: ...WaterComm Installation and User Instructions ...

Page 2: ... the email or SMS notification gives precise date time and location information IMPORTANT NOTE Prior to installation please ensure that Leaksafe is provided with a mobile phone number where equipment test SMS s will be sent during installation This can be amended following installation so that future alarms are sent to whoever will be managing the system Contact Leaksafe on 0344 848 0488 or info l...

Page 3: ...d can be daisy chained together if longer lengths are required If the system is being used as a centrally located panel then the connecting cable can be extended using either 2 wire 13 core audio cable or YY 0 05mm2 cable No more than 25M of cable and tape can be connected in a single length To daisy chain lengths of leak detection tape push the male female connectors at the end of the tapes toget...

Page 4: ... leak was detected The notifications will look like this SMS Notification Re Property location e g XX House Flat XX Kitchen Leak detected Battery level x xx Temperature xx xx Humidity level xx xx LeakSafe WaterComm Device PLEASE NOTE that the leak detection tape is deliberately sensitive and will activate with just a few drops of water Email Notification From noreply m3h co uk Subject Alert from L...

Page 5: ...ed into the Leaksafe RM device Once a day behind the scenes each WaterComm monitors its battery level the ambient temperature and humidity and whether the connected tape is wet We call this a daily heartbeat If a leak alarm has been activated and the tape is still wet when the next daily heartbeat is transmitted you will receive a further notification and will continue to receive them every 24 hou...

Page 6: ...Version 1 January 2022 Leaksafe Solutions Limited Unit C Rose Court 89 Ashford Road Bearsted Maidstone ME14 4BS United Kingdom Tel 0344 848 0488 Web www leaksafe com Email info leaksafe com ...