background image

Leaf LTHDMI88 / LTHDMI88E manual 

 

Page  12  Of  16 

 

The calibration process may take up to a minute or two and when finished, the 
LEDs will display (green) the previously selected sources and zones. 

5.3  Clear all connections / Global OFF 

The  following  steps  describe  the  manual  operation  required  if  using  the  press  button 
switches on the LTHDMI88 /E. Note that this process is not directly accessible by Leaf 
TC3. 

  Hold the lower button 

(B)

 for 3 seconds to clear all connections and set the unit 

to standby mode.  

  Standby mode will be indicated by one single pulsing green/blue LED.  

5.4  Creating new input / output connections. 

  Press  the  lower  button 

(B)

  to  enter  selection  mode.  THE  SELECTION  MODE 

LEDS WILL BE BLUE. 

  Press  the  lower  button 

(B)

  sequentially  until  the  LED  in  the  lower  row 

corresponding to the desired output (zone) is blue. 

  Press  the  upper  button 

(A)

  sequentially  until  the  LED  in  the  upper  row 

corresponding to the desired input (source) is blue. 

  After  a  few  seconds  the  connection  will  be  made,  and  these  LEDS  will  turn 

Green. 

Notes: 

1.  If  neither  button  is  pressed  for  an  extended  time  (approx  10sec),  the 

display  will  revert  back  to  display  mode  (displaying  input/output 
connections). 

2.  If in the third step above the upper button 

(A) 

is pressed until no BLUE 

LED are displayed in the upper row, the connection will be cleared - i.e. 
the output will be disconnected from the input. 

Summary of Contents for LTHDMI88

Page 1: ...LTHDMI88 LTHDMI88E ...

Page 2: ...DMI88 LTHDMI88E manual Page 2 Of 16 Document Status Client Nexus Status Controlled external release Authorised by AFG Comment Closure Date Revision History Version Date Changes 1 10 08 11 Initial release 2 3 4 ...

Page 3: ...PLE LTHDMI88 E USE 8 3 3 Bank Select Switch 8 3 4 IP port 9 3 5 RJ12 control port 9 3 6 4 way DIP switch module 9 3 7 Audio ports 9 3 8 3 5mm IR ports 9 3 9 RJ45 type Through RS232 ports 10 3 10 HDMI Input ports 10 4 FEATURES 10 4 1 EDID Management 10 4 2 Calibration 10 4 3 Exclusive Source Selection 11 5 OPERATION 11 5 1 Apply Power 11 5 2 Calibration 11 5 3 Clear all connections Global OFF 12 5 ...

Page 4: ...TB1E breakouts Interconnection between a Leaf True interface and associated Leaf True breakouts is via one single cat5E 6 cable for each breakout Single cat5e 6 cable interconnect between these components is made possible through the use of HDBaseT technology This technology enables Ethernet IR RS232 Video and Audio to be all sent by a single cable per zone over large distances Cabling specificati...

Page 5: ...l except for the addition of an additional row of 8 x RJ45 type ports for Ethernet connection 2 1 HDBase T Connections Each Leaf True breakout is connected to the interface by way of a single Cat5e 6 cable to the HDBaseT output or zone ports across the lower part of the front panel 2 2 Ethernet Ports The Ethernet ports across the upper part of the front panel of LTHDMI88E are for connection of Eth...

Page 6: ...be off or on in one of 3 different colours corresponding to different operation modes 2 3 1 1 GREEN LEDS DISPLAY MODE When the LEDs are green the top row of LEDs indicate the inputs sources that are connected to an output zone The lower row of LEDs indicate the outputs zone that are connected to an input source 2 3 1 2 BLUE LEDS SELECTION MODE After a button is pressed the display is in selection ...

Page 7: ...sets of RCA line level stereo and SPDIF audio sockets 8 x 3 5mm Tip Ring Sleeve sockets for connection of IR devices 8 x RJ45 type RS232 serial data ports 8 x HDMI Input or source ports 3 1 4 pin DIN power connector The LTHDMI88 E requires 4 Pin 12V power WARNING Failure to use the correct power supply as provided by Leaf Audio may result in incorrect operation and or damage to the Leaf True Matri...

Page 8: ...e all other units in the chain must have this switch set to OFF Down The RS232 Input port is used for controlling the units 3 3 Bank Select Switch The BANK rotary switch selects the RS232 bank address for the unit as per the following Bank Select Table BANK SELECT SWITCH LTHDMI88 E OUTPUT ADDRESS ZONE NUMBER Position Physical Logical Hex 0 1 to 8 0 to 7 00h to 07h 1 9 to16 8 to 15 08h to 0Fh 2 17 ...

Page 9: ...detectors or devices at LTHDMI88 E IR TX blasters at LTB1 E breakouts 2 IR Input device type Applies when DIP 1 ON IR RX detectors eg Leaf Hammerhead at LTHDMI88 E IR Input device type Applies when DIP 1 ON IR direct drive from control system 5 volt only at LTHDMI88 E 3 Future Function Future Function 4 Future Function Future Function Table 2 Dip Switch Settings 3 7 Audio ports The Stereo Analog a...

Page 10: ...ludes support of 3D formats 4 FEATURES 4 1 EDID Management The Extended Display Identification Data EDID of all sinks TVs Display Panels etc attached to a zone are merged and presented to the source This ensures that the source outputs the correct audio and video format to all sinks When a sink is switched to a source the LTHDMI88 remembers its EDID After a calibration or each time new sinks are s...

Page 11: ...a global command is sent then the existing source is unlocked Locking a zone to a source that is already switched to one or more other zones will cause that source to disconnect from those zones 5 Operation 5 1 Apply Power Once power is applied to the LTHDMI88 LTHDMI88E it will go through a Power Up routine lasting a minute or two The display LEDs will cycle blue through all source zone connection...

Page 12: ...ng new input output connections Press the lower button B to enter selection mode THE SELECTION MODE LEDS WILL BE BLUE Press the lower button B sequentially until the LED in the lower row corresponding to the desired output zone is blue Press the upper button A sequentially until the LED in the upper row corresponding to the desired input source is blue After a few seconds the connection will be ma...

Page 13: ...I88 LTHDMI88E manual Page 13 Of 16 6 Interconnections 6 1 Possible interconnections at front panel LTHDMI88E depicted LTHDMI88 is similar but without the Ethernet ports 6 2 Possible interconnections at rear panel ...

Page 14: ...Leaf LTHDMI88 LTHDMI88E manual Page 14 Of 16 6 3 Possible interconnections at LTB1E LTB1 is similar but without the Ethernet port ...

Page 15: ...S232 DB9 IN 1x RS232 DB9 LOOPOUT 1x IP control Bank select and termination selectors 6 REMOTE CONTROL TO BREAKOUTS 8x DIRECTIONAL IR INPUTs Support for Direct IR IR TX Bug IR RX Bug Modulated 38Khz and Envelope 8x RJ45 RS 232 PORT for remote control to breakouts Up to 115200 Baud 7 DISPLAY KEYS Front Panel with 2 push switches and 16 LEDs enable basic selection and display of the connections withi...

Page 16: ...I output 10 2Gb S full bandwidth deep color 3 OUTPUTS ETHERNET LTB1E only 1x ETHERNET OUTPUT 4 OUTPUTS RS232 1x RS 232 PORT BLACK RJ45 CONNECTOR Up to 115200 Baud 5 OUTPUT IR IR LED DRIVER 38KHz OR IR INPUT Selected by main unit 3 5mm TRS female connector 7 NUMBER OF INPUTS OUTPUT 1 8 POWER Local power required 12W 1A 12V 9 DIMENSIONS W D H 116mmx121mmx31mm 36mm with wall plate fitted ...

Reviews: