background image

Leaf LT2020E manual 

Page  8 

Of  18 

3.1  RJ12 control port 

The   6 wire  RJ12  port  enables  the  LT2020E  to  be  controlled  by a proprietary 

LEAF controller such as the TC3.  

3.2  4 way DIP switch module 

The rear panel accessible 4 position DIP switch controls functionality of the LT2020E. 
The  table  below  summarizes  the  settings:  The  individual  switches  are  labelled  with 
their switch number and ON 

– OFF position.  

NOTE: The interface will only read the DIP switch settings on power-up. The unit must 
be powered off and then back on again for it to respond to any change of the DIP 
switch settings.  

DIP SWITCH 

OFF (UP) 

ON (down) 

Global IR direction IN 

IR RX detectors at LTB1E 

breakouts 

 IR TX blasters at L

T

2020E 

Global IR direction OUT 

IR RX detectors or devices at   

LT2020E 

IR TX blasters at LTB1E breakouts

 

IR Input device type  

(Applies when DIP 1 =ON) 

IR RX detectors (e.g. Leaf 

Hammerhead) at   

LT2020E 

IR Input device type  

(Applies when DIP 1 =ON) 

IR direct drive from control 

system*  (5 volt only) at LT2020E 

*Must connect IR IN with a stereo

(tip,ring,sleeve) lead / modified

stereo lead or Mono lead with 

suitable adaptor.(Ref: sect 3.5) 

Normal Mode 

Compatibility Mode 

Future Function 

Future Function 

Table 1: Dip Switch Settings 

3.3  Digital Coax (S/PDIF) audio inputs: 

The upper row of RCA sockets 1 to 16 are configured as digital coax (S/PDIF) stereo 
audio input ports. They can be used as either alternative audio inputs (selectable with 
discrete Audio Only commands) or the input points for audio only sources. 

3.4  Stereo RCA analog outputs 

The lower 2 rows of RCA sockets 1-16  are configured as stereo analog audio outputs 
for connection to local devices such as centralised external amplifiers.  

The  source  audio  for  these  outputs  can  be  either  an  HDMI  input  source,  digital  coax 
(S/PDIF) stereo connector input or audio return from a zone breakout input.  

The RCA outputs may be routed manually or automatically (the default). 

With automatic routing active, the RCA audio outputs will follow the zone audio output 
of  the  same  number.  (example:  If  zone  4  is  selected  to  source  2,  then  in  automatic 
mode the RCA audio will also come from source 2).  

Summary of Contents for LT2020E

Page 1: ...LT2020E...

Page 2: ...tem and any equipment that is to be connected to it prior to connecting any leads cables Plug in and switch power back on again after all interconnection leads are in place Do not run HDBaseT Zone Cat...

Page 3: ...h ports 10 3 7 4 pin DIN power connector 10 3 8 RS232 Serial Control connectors 11 3 8 1 Single LT2020E use 11 3 8 2 Multiple LT2020E use 11 3 9 RS232 Termination TERM Switch 11 3 10 HDMI Input ports...

Page 4: ...kouts is via one single cat5e 6 6a four pair cable for each breakout Single cat5e 6 6a cable interconnect between these components is made possible through the use of HDBaseT technology This technolog...

Page 5: ...ed HDBaseT outputs for connection to the zone breakouts LTB1E 2 16 x ethernet RJ45 type ports for connection of optional ethernet equipment 3 A Touch Screen control panel 2 1 HDBase T Connections Each...

Page 6: ...nection is 100Base T full duplex An external Ethernet router switch may be added for added flexibility and performance The Orange LED on the Ethernet ports indicate handshake between the LT2020E and h...

Page 7: ...digital coax audio input sockets 4 16 x pairs of RCA line level stereo output sockets 5 16 x RJ45 type RS232 serial data ports 6 16 x 3 5mm Tip Ring Sleeve sockets for connection of IR devices 7 1 x...

Page 8: ...l system 5 volt only at LT2020E Must connect IR IN with a stereo tip ring sleeve lead modified stereo lead or Mono lead with suitable adaptor Ref sect 3 5 3 Normal Mode Compatibility Mode 4 Future Fun...

Page 9: ...h 1 ON down the IR ports on the LT2020E can be further configured by DIP Switch 2 to accept direct IR drive from an external control system or similar instead of stand alone IR detectors See table 1 f...

Page 10: ...2 connection may require the additional of M M gender bender s For convenience the pinouts of the RJ45 type RS232 through ports is shown below 3 7 4 pin DIN power connector The LT2020E requires 4 Pin...

Page 11: ...le LT2020E use Multiple units can be chained together and addressed on the same RS232 link by connecting the RS232 thru out port on one unit to the RS232 input port of the next unit The last unit in t...

Page 12: ...r Each breakout LTB1E is required to be powered by its own local power supply and to be connected via a Cat5e Cat6 Cat6a four pair cable link from its HDBaseT port to the associated HDBaseT port on th...

Page 13: ...LED 2 ON The HDBaseT Cat5e Cat6 cable link to the LT2020E has been made successfully and is ready for video LED 3 ON Protected HDCP video content is being transferred on the HDBaseT link FLASHING Non...

Page 14: ...Ref sect 6 2 5 3 Exclusive Source Selection Zone Lock mode A source can be locked to a particular zone The exclusive source selection feature enables enhanced features such as multichannel audio 3D e...

Page 15: ...g output connectors on the LT2020E The source range for the selected audio inputs under this feature becomes HDMI input ports 1 to 20 LTB1E Breakouts 21 to 37 LT2020E 41 to 56 This feature is activate...

Page 16: ...y by following these steps 1 Turn on all sources and zone equipment AV receiver or TV Ensure that zone equipment AV receivers TV s etc are set to the correct HDMI input 2 Calibrate the system by follo...

Page 17: ...rietary Remote control 1x RS232 DB9 IN 1x RS232 DB9 LOOPOUT Bank select and termination selectors 6 INFRA RED REMOTE CONTROL THROUGHPUT ONLY No direct control by IR 16x DIRECTIONAL IR INPUTs Support f...

Page 18: ...ing antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an...

Reviews: