©MMXI - LEADER LIGHT – All right reserved
Edition: A - 2011
Additional information on [email protected]
Page 2 /2
Camloc 1/4 turn fasteners
Safe mechanical quick release
fastener systems
Locking/unlocking by quarter turn
Hand operated
Service-friendly, time-saving
and cost cutting
Vibration-resistant
-
-
-
-
-
Mechanical mounting of LL STAGE WASH
03.4 Control data connection
Control data cable length is specified by Norm IEC929 Annex E4.
It is not necessary to open the fixture before connecting of DMX512 control sig
-
nal. Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
03.5 DMX channels
These informations are subject to change, latest data are on: www.leaderlight.eu
05 MAINTENANCE AND SERVICE
Before any maintenance is necessary to carefully read all
SAFETY INFORMATION 01!
Damages caused by inadequate cleaning or maintenance are not covered by warranty.
Requires periodic cleaning (dust, dirt ,...)
Procedure for maintenance:
Unplug mains before maintenance and at least 10 minutes cool off.
Appliance do not illegal open or demount.
Clean-up dust only from outer surface. Use vacuum or dumpy duster (warm
water)
Before reinstalling make sure everything is intact and dry– no wet parts!
Service:
Customer service provided by the manufacturer.
-
-
-
-
-
-
-
-
!
Ch.
RGBAW
AW
AWUV
Mode1: Dip2=Off
1
R 1, R 2, R 3
A 1, A 2, A 3
A 1, A 2, A 3
2
G 1, G 2, G 3
W 1, W 2, W 3
W 1, W 2, W 3
3
B 1, B 2, B 3
Master (Dip1=On, Dip4=Off)
UV 1, UV 2, UV 3
4
A 1, A 2, A 3
Strobo (Dip1=On, Dip4=Off) Master (Dip1=On, Dip4=Off)
5
W 1, W 2, W 3
Strobo (Dip1=On, Dip4=Off)
6
Master (Dip1=On, Dip4=Off)
7
Strobo (Dip1=On, Dip4=Off)
Mode4: Dip2=On
1
R 1
A 1
A 1
2
G 1
W 1
W 1
3
B 1
A 2
UV 1
4
A 1
W 2
A 2
5
W 1
A 3
W 2
6
R 2
W 3
UV 2
7
G 2
Master (Dip1=On,Dip4=Off)
A 3
8
B 2
Strobo (Dip1=On, Dip4=Off)
W 3
9
A 2
UV 3
10
W 2
Master (Dip1=On,Dip4=Off)
11
R 3
Strobo (Dip1=On, Dip4=Off)
12
G 3
13
B 3
14
A 3
15
W 3
16
Master (Dip1=On,Dip4=Off)
17
Strobo (Dip1=On, Dip4=Off)
Extention and control functions:
Dip4=Off, Dip1=Off =>DipBCD:
use rotating switch for DMX start address
(RS1-100, RS2-010, RS3-001) from 001 to 512
Dip4=Off, Dip1=On: 2channels (Strobo)
Dip4=On, Dip1=Off: switch on AutoRun-table functions:
“100“=Prg.0-9, “10“=StepTime, “1“=FadeTime
Dip4=On, Dip1=On: switch all channels on 50% - test function
Dip2=Off: Mode 1 (5+2ch)
Dip2=Off: Mode 1 (2+2ch)
Dip2=Off: Mode 1 (3+2ch)
Dip2=On: Mode 4 (15+2ch)
Dip2=On: Mode 4 (6+2ch)
Dip2=On: Mode 4 (9+2ch)
Dip3=Off: standard curve
Dip3=On: ultraSoft curve
Mechanical mounting of tubus and frame to the LL STAGE WASH
Vario Optic installation
2.1 Fit the tube LL37 300 / LL37 303 part on top of fitting. The tube screws screw into the fitting holes.
The tube is ready to use.
Tube and frame installation without tools (Figures Nr. 2.1 to 2.2).
2.2 The frame must be installed together with tube LL37 303. The frame mount with screws on the
top of tube.
It is not necessary to open the fixture for echange of Vario Optic (Figures Nr. 3.1 to 3.2).
3.2
Carefully remove the optic modul and insert the new one and fix with screws.
3.1 The optic installation is easy and fast by 2 screws.
180°
AIMING POSSIBILITY
The fixture could be aim to wish position with
adjustable bracket.
Mounting on stage is easy using various accessories as seen below (Figures Nr. 1.1 to 1.4). The brackets are connect by Camlocs.
1.1 Serial connection by LL36 600 for creation of continuous line
1.2 Serial connection by LL36 610 for creation of line with extension
1.4 Parallel connection by triple bracket LL36 630
1.3 Parallel connection by dual bracket LL36 620
LL36 620
LL36 630
LL36 600
LL36 610
04 PERNAMENT USE LIMITATIONS FOR HEATING DISSIPATION
Pernament use limitations for heating dissipation of LL STAGE WASH RGBAW - body
temperature must be less then 55°C
40°C ambient temperature -20% of total power
30°C ambient temperature -10% of total power
20°C ambient temperature 0% of total power
Black version - 30%
Silver or White version - 50%
Example:
Then final pernament value for BLACK colour and 40°C ambient temperature = -30% -20%
= 56% = max 143 ≥ (R + G + B + W +A) / 5
It‘s mean average of power go inside the fixture at DMX signal
Example:
black LL STAGE WASH: 180 ≥ (R + G + B + W + A) / 5
silver LL STAGE WASH: 128 ≥ (R + G + B + W +A) / 5
Values for R or G or B or W or A is 100% = 256 = 8bit levels *** RED 50% = 128 value, RED
75% = 192 value
Final information we don’t drop down each colour power with temperature control to
get maximum for each colour under total recomendations , therefore you need setup
limitations from control desk !!!
-