NOTE:
It is recommended that fixture be attached securely by drilling through the back of fixture and attaching to mount-
ing surface (hardware not supplied). When drilling fixture, care must be taken to avoid drilling close to ballast or within
1/4" of sides of fixture. All unused entries must be plugged. Use weatherproof silicone sealant to insure proper seal.
. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION
OF THE PRODUCT AND THE HAZARDS INVOLVED. Fixture should not be used in areas with limited ventilation
or high ambient temperatures. Installation should be done by a qualified electrician.
WIRING
IF SUPPLY WIRES ARE LOCATED WITHIN (3) INCHES OF BALLAST, USE WIRE RATED FOR AT LEAST 150°C.
IF SUPPLY WIRES ARE ROUTED AND SECURED MIN. (3) INCHES
AWAY FROM BALLAST, USE WIRE RATED FOR AT LEAST 90°C.
1. Connect the 120v lead from ballast to the black supply lead.
2. Connect the “com” lead to white supply lead.
3. Fixture ground screw must be connected to supply ground.
Thank you for buying RAB lighting fixtures. Our aim is to design the best quality products so you can get the
job done right. We’d like to hear your comments. Call us at 888-RAB-1000, attention Marketing Department.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
RAB Vandalproof fixtures must be wired in accordance with the National Electrical Code and applicable local codes.
Proper grounding is required for safety
WARNING
:
Make certain power is OFF before installing or maintaining fixture.
LOCATION
Fixture should be ceiling mounted; but should not be recessed.
MOUNTING
For Fluorescent and Incandescent models
where no housing exists:
1. Remove refractor.
.
2. Mount reflector to junction box and/or wall surface with
appropriate hardware.
3. Connect fixture leads to supply leads.
4. Install lamps and replace refractor.
For HID models and Fluorescent models with bronze
ballast housing:
1. Remove refractor and reflector plate.
2. Remove knockouts in housing for desired conduit entrance
(see mounting note below)
3. Connect fixture ballast leads to supply leads with wire nuts.
4. Replace socket mounting plate; install lamp and refractor.
TAMPERPROOF SCREWS
RAB Vandalproof fixtures are shipped with both standard screws and tamperproof screws.
For maximum security, insert tamperproof screws into the refractor and tighten with Center Pin Torx Screwdriver
(catalog #Vandriver, not supplied).
VAN11 & 15 INSTALLATION INSTRUCTIONS
®
(+) LINE BLACK
(–) COMMON WHITE
ER
UT
XI
F
LP
PU
S
Y