16.
Place the pan gasket against the front of the flue pan. If
necessary secure it with tape or optionally use a
LEADER pan gasket holder (Order #59210).
17.
Install an angle valve assembly into the couplers located
on the front sides of the flue pan. Thread tape all
stainless steel threads. Make sure the handles open
away from the syrup pan.
18.
Thread a 1” hex nut onto the exposed end of each angle
valve assembly. Turn down until the front of the nuts
are lined up approximately with the center of the pan
gasket.
19.
Slide the holes in the hot sap float boxes of the
syrup pan over the angle valve assemblies. Push
on the pan in order to compress the pan gasket
in order to install the rail gasket at the front of
the syrup pan.
20.
Place a piece of 1” rail gasket cut 4” wider than
the flue pan, in front of the syrup pan to cover
the opening between the syrup pan and the
arch.
14.
Tighten the ¼ X 20 nut closest to the flue pan on each
of the machine screws.
15.
Move the outside pairs of ¼ X 20 nuts in and out until
the regulator box is level along the narrow edge.
When it is level tighten the outer nut of each pair
against the inner nut.