![Leader Evaporator PATRIOT MAX Manual Download Page 10](http://html1.mh-extra.com/html/leader-evaporator/patriot-max/patriot-max_manual_1864736010.webp)
PATRIOT MAX & STANDARD EVAPORATOR PAN SET 2019
Page:
10
7.
Insert a supplied ¼ - 20 X 3” stainless steel machine screw RH
through each of the mounting holes in the flue pan located
above the regulator box connection pipes. The head of the
screw will be inside the flue pan.
8.
Thread a supplied ¼ - 20 stainless steel nut onto each of the
machine screws. Turn the nut towards the flue pan until the
screw is held into position – do NOT tighten the nut.
9.
Thread a second supplied ¼ - 20 nut onto each screw and
turn the nut until it is approximately 1 ½” down on the
machine screw.
10.
Align the regulator box connections with the rubber
connectors on the flue pan.
11.
Tilt the regulator box top slightly away from the flue
pan and while straightening the regulator box, slide the
regulator box connectors into the rubbers connectors
on the flue pan and the machine screws in the flue pan
into the mounts on each side of the regulator box.
12.
Thread a supplied ¼ - 20 nut onto each of the machine
screws and finger tighten against the nut on the
machine screw. This will hold the regulator box in
place.
13.
Press the regulator box into the rubber connectors.
Ensure the band clamps on each connector are located
over the connector pipe on the regulator box and face
screw down then tighten the clamps.