HYDROMETER FUNCTION 

A hydrometer works based on the density of the maple syrup.  There are two scales on the hydrometer; Brix and Baume.  
The Brix scale indicates the percentage of sugar in the maple syrup.  The Baume scale is a measure of how dense the 
maple syrup is related to the density of water.  The correct density for maple syrup is a minimum of 66% sugar 
(66°Brix/35.6°Baume).  You will need to verify your state’s rules and adjust your readings as necessary.  The hydrometers 
supplied by LEADER EVAPORATOR have been calibrated at two temperatures; 60°F Cold Test (66.9°Brix/36°Baume) and 
211°F Hot Test (59.1°Brix/32.1°Baume).  The maple syrup is expected to be at the upper temperature when it is 
measured immediately after being drawn off the evaporator.   

NOTE:  Hydrometers from Leader Evaporator by law are calibrated by the State of Vermont.  .  The HOT and COLD test 
lines should be considered guidelines.  Hydrometers should only be used by reading temperature and Brix/Baume 
readings. 

USE OF A HYDROMETER 

NOTE:  Hydrometers are very fragile.  Two most susceptible points of damage during use are the bottom and where the 
stem meets the body.  Take extreme care when handling a hydrometer. 

As hydrometers are susceptible to damage it is recommended the sugar house have a spare.   

PREPARING A NEW HYDROMETER FOR USE: 

1.

 

Unpack the hydrometer from its tube or box. 

2.

 

Carefully inspect the hydrometer for any breakage.  If you 
suspect any cracks, fill your test cup with hot water and 
immerse the hydrometer.  If it leaks then it is damaged and 
can’t be used. 

3.

 

Place the hydrometer in its original container seated in the 
packaging and mark the container where the bottom of the 
hydrometer aligns. 

4.

 

Mark the container at the same lines as the HOT and COLD 
test lines in the hydrometer.  When using the hydrometer in 
the future these lines are a check to ensure the scale inside 
the hydrometer has not moved. 

USING THE HYDROMETER 

1.

 

Prior to using the hydrometer for the day, place it into its original container and check the hydrometer lines 
against the lines you marked on the container.  If they do not match then replace the hydrometer. 

2.

 

Ensure the hydrometer is clean prior to every use.  Accumulated material on the hydrometer will cause the 
hydrometer readings to be incorrect as it will have extra weight and not float as easily. 

3.

 

Hold the test cup upright.  Fill the test cup up to ½” to ¾” from the top with the syrup to be tested or from the 
syrup section of the syrup pan.   DO NOT HAVE THE HYDROMETER IN THE CUP. 

4.

 

Do not allow the syrup to cool.  Place the cup on a level surface.  Immerse a thermometer into the test cup.  
Slowly immerse the hydrometer into the syrup in the test cup until it reaches the “HOT” test mark then carefully 
release it.  NEVER DROP THE HYDROMETER INTO THE TEST CUP. 

5.

 

Read the temperature from the thermometer. 

 

6.

 

Read the Brix or Baume number from the hydrometer. 

Summary of Contents for Half Pint Evaporator

Page 1: ...Leader Evaporator Co Inc 49 Jonergin Drive Swanton Vermont 05488 802 868 5444 www leaderevaporator com Leader Half Pint Evaporator...

Page 2: ...9 POSITIONING 9 BRICKING 9 SETTING THE PANS 12 INSTALLING THE DRAW OFF VALVES 12 First Boil 13 OPERATION OF THE HALF PINT EVAPORATOR 14 THEORY OF OPERATION 14 GRADIENT 14 MAKING SYRUP 16 FLOW REVERSAL...

Page 3: ...and another small batch is drawn off Sap is boiled only long enough to make syrup By limiting the time heating and reheating the sap the caramelizing of the sugars will be reduced Reducing the caramel...

Page 4: ...ront 1 Back 1 Left 1 Right 1 Bottom 1 G Grate Rail 2 Draft Latch Bolt and Nut 10 24X 1 1 Draft Latch 1 I Corner Bracket 2 J Corner Bracket 2 J 3 Holed Steel Legs 4 H Grate Assembly 1 Machine Screws 20...

Page 5: ...aporator The following parts can be ordered as a kit Order 302435 of individually as listed Fire Brick Full qty 32 65003 Fire Brick qty 63 65006 Rail Gasket X 2 x 25 roll 65154 Refractory Cement 65001...

Page 6: ...r assembly Bolts should be inserted into arch so the heads are exposed and the threads are inside the arch Finger tighten bolts unless otherwise instructed 1 Mount Left and right panel to the bottom p...

Page 7: ...carpenter s square and tighten all the bolts in that corner All flanges should align Repeat until all four corners are complete 9 Tighten all remaining installed bolts 10 Use 20 X bolts and associated...

Page 8: ...latch should be pointed towards the front of the arch To ease the installation you may remove the door by pulling the hinge pin that connects the door to the arch front 13 Install the grates assembly...

Page 9: ...for 3000 F To apply cement completely skim coat the metal of the arch where the brick is to be installed Put about 1 8 on each edge of the brick to be installed and a skim coat on the side facing the...

Page 10: ...as illustrated Remember to coat the edges of the bricks with approximately 1 8 of refractory cement 5 The end bricks of the bottom row will be behind the bottom row of the full bricks when the sides a...

Page 11: ...e as much as possible then retighten the bolts If the bricks still do not fit trim the length of the brick 7 The first row of bricks toward the arch front should be up against the bolts in the side of...

Page 12: ...h Teflon tape 4 Screw the supplied brass lead free ball valve onto one end of the stainless steel nipple The assembly is referred to as the reservoir pan faucet INSTALLING THE DRAW OFF VALVES It is re...

Page 13: ...done to remove any residual materials from the pans and to season the bricking and insulation 1 Prepare 15 gallons of a baking soda and water mix in proportion as follows a 1 1 4 ounce of baking soda...

Page 14: ...ntrated liquid sap will push its way toward the more concentrated liquid In an evaporator you will be concentrating the percent of sugar from the incoming sap approximately 2 to the syrup product appr...

Page 15: ...consistently with small amounts of wood to maintain the level of heat Use a timer to stay on schedule for the firings 6 to 10 minutes depending on wood quality size and desired intensity of boil TIP F...

Page 16: ...e following is the recommended method for determining the draw off temperature a The sap will turn an amber or darker amber color b The temperature of the sap will reach 7 0 to 7 5o F above the boilin...

Page 17: ...ervoir pan into a container 3 Turn the reservoir pan 180 and move to 6 from the rear of the boiling pan 4 Refill the reservoir pan level to 2 3 to 5 Fill the boiling pan to the operating level 1 6 Sta...

Page 18: ...ck the hydrometer from its tube or box 2 Carefully inspect the hydrometer for any breakage If you suspect any cracks fill your test cup with hot water and immerse the hydrometer If it leaks then it is...

Page 19: ...d will need to be diluted with sap 7 Refer to the chart to determine if your syrup is light or heavy If the reading is higher than the number on the table your syrup is heavy and will need to be dilut...

Page 20: ...s brush the loose scale f If scale is removed flush the pan with unsoftened non chlorinated well or spring water If the scale is thick you may need to continue soaking the solution in the pan g When t...

Reviews: