6. Service and Maintenance
6.1.2 Installation of the Vaporizer
• Connect the machine to the battery, press the blue button [11] at the back of
the machine once and disconnect the machine from the battery
• Plug the blue fluid tubing (8) onto tubing spout (9) of the new vaporizer
• Plug the male connector strip (10) of the vaporizer into the female connector
strip of the unit
• Connect the pump cable (6) to the vaporizer
• Check the connections once again and make sure that the fluid tubing is not
twisted or bent
• Fasten the casing cover with the two screws (5). Ensure that the base of the
casing and the vaporizer engage into the corresponding guide grooves of the
lid part
6.1.3 Calibration of the Vaporizer
Since all evaporators have different electrical qualities, the TINY-FOGGER must
be calibrated after every exchange of the vaporizer.
IMPORTANT: During the calibration process the vaporizer temperature must be
at 20
°
C. Never start fogging before the calibrating process. Too cold or too warm
units must first adapt to the room temperature (20
°
C).
• With the battery disconnected press and hold down the blue button [11] at
the back of the machine.
• Connect the battery clip to the battery and then release the button. The yellow
LED (battery status display) will flash six times with a short pause after the
second and the fourth flashes.
• The calibration process is now complete.
6.2 The machine does not work perfectly
• the battery is discharged (yellow charge indicator (LED) lights up permanently,
the pump automatically cuts off) => charge the battery
• the fluid tank or the fluid tubing is empty or the connecting spout of the fluid
tubing is not correctly plugged into the quick connector on the fluid tank
=> refill the fluid tank, check to see that the tubing plug is properly fitted to
the quick connector
• the vaporizer is clogged or broken => change the vaporizer (see point 6.1)
6.2.1 There will be no fog if…