Connection to public address system with SIME (MPS-8Z with ZES22 matrix)

Support Handbook - LDA MPS-8Z S02

 1.2 

RS-485 Connection

In order to properly connect MPS-8Z microhone and ZES-22, it is mandatory to do it by an
specific UTP cable. This cable should be CAT 5 or higher.
Starting with the attached diagram (Picture 3), the next connection must be followed 

This will be the input connector for MPS8-Z Microphone (ACSI bus). 

Next step, the wiring connection to ZES-22 must follow this pinout indicaions:

1. (Striped Orange): Audio +

2. (Orange): Audio -

3. (Striped Green): GND

4. (Blue): RS-485 A

5. (Striped Blue): RS-485 B

6. (Green): GND

7. (Striped red): + 24 V

8. (Red): + 24 V

This wiring must be connected by a three ways Euroblock connector, getting split  two
connector for RS-485 and audio input ports.

As shows on Picture 4 indications,  this wires connect to tags number 4 (input/output
ZES-22 ports) and number 8 (RS-485). Furthermore, the audio input CH3 must be the

used one for a correct setup.

Picture 3: RJ45 Type B pinout diagram