24
Wiring and operating the Diesel Fueling Station
The Diesel Fueling Station requires two ASC2 outputs and accessory ID#s. Refer to the figure
below to wire the Diesel Fueling Station (available separately) to output numbers 7 and 8.
Figure 17. Diesel Fueling Station wiring diagram. Operation uses two TMCC ID numbers.
1. Press ACC on the CAB-1L remote controller.
2. Press 7 on the CAB-1L remote controller to address the accessory.
3. Press AUX2 to turn on the lamps.
4. Press AUX2 again to turn them off.
5. Press ACC on the CAB-1L.
6. Press 8 on the CAB-1L.
7. Press and hold AUX1 and the attendant will come out for as long as you hold the
button down.
LCS PDI CABLES
use either connector
AC Power
PROGRAM
A U A
U
SWITCH
ACCESSORY
SWITCH
ACCESSORY
COMM
COMM
4 O
8
4 T
7
3 O
6
3 T
5
2 O
4
2 T
3
1 O
2
1 T
1
ASC2
6-81327
Diesel Fueling
Station
(bottom view)
Accessory
Transformer
U
A
Follow these steps to operate the Diesel Fueling Station.
Accessory examples