background image

Model 8310-2420

Installation Instructions

Description

Actuators

Available faceplates:
Dual Single Gang “Push to Open/Push to Lock” with 

illuminated flush mount box
Double Gang “Push to Open” with illuminated flush mount 

box

E-strike

Provided faceplates:

•  4-7/8” x 5/8” (ANSI Square/Hollow Metal)

•  6-7/8” x 5/8” (Aluminum)

•  7-7/8” x 5/8” (Wood Door)

•  Transformer

•  Open style, channel bracket, two-hole chassis mount.

•  120 VAC @ 60 Hz.

•  Minimum 6” leads

•  Class B insulation (130° C)

Cabinet

•  11-1/16” x 7-7/8” x 2-11/16”

•  Power Supply (blue circuit board), Relay Module (green 

circuit board), and two terminal buses

•  Must be set to 24VDC output

Parts lists

Main parts list

Item 

#

Description

Quantity

1

“Push to Open” switch

1

2

“Push to Open/Push to Lock” combo 

switch

1

3

LED electrical board

2

4

LED diffuser

2

5

Power supply/relay cabinet

1

6

Door position switch

1

7

Flush mounting boxes

2

Item 

#

Description

Quantity

8

“Wait for Door to Close” vinyl decal

1

9

“Door locked when red/unlocked when 

green” black vinyl sign

1

10

“Door occupied when red/vacant 

when green” black vinyl sign

1

11

E-strike with 3 faceplates and 

hardware (see the E-strike parts list 

below)

1

12

Transformer

1

E-strikes parts list

Item 

#

Description

Quantity

1

E-strike (comes pre-installed w/ ANSI 

faceplate)

1

2

Aluminum faceplate

1

3

Wood faceplate

1

4

Faceplate template

3

5

24V female connector

1

6

Varistor (MOV)

1

7

Trim plate

1

Item 

#

Description

Quantity

8

Mounting brackets

2

9

Wire nuts

4

10

#10-32 x 1/2” machine screws 

(installed w/ ANSI faceplate on 

e-strike)

2

11

#10 - 11/4” wood screws (used for 

mounting brackets to wood frame)

2

12

M5 x 12mm machine screws (for 

mounting brackets - 2 screws for 

securing the frame brackets and 2 

screws for securing the electric strike)

4

8310-2420 Push Plate Restroom Kit

CAUTION

The product warranty will be voided if the product is mounted for an exterior door and/or is exposed to elements.

For cleaning purposes, do not expose components to extreme wash-down.

The electric strike is not water-proof.

Summary of Contents for 8310-2420

Page 1: ...for Door to Close vinyl decal 1 9 Door locked when red unlocked when green black vinyl sign 1 10 Door occupied when red vacant when green black vinyl sign 1 11 E strike with 3 faceplates and hardware...

Page 2: ...B2 Power 50 VA DPS Switch Descriptions 8310 2420 Series Power max 3 0 W Electrical configuration SPDT Suggested Wiring 22AWG Gap distance max 0 75 Operation at a glance When the exterior PUSH TO OPEN...

Page 3: ...onic board in place 1e Place the diffuser insert inside the flush enclosure making sure the mounting screw holes on the diffuser insert and the flush enclosure align For Push to Open switches a Use th...

Page 4: ...Safe mode when Mode Selector is pointing to FS Fail Lock mode when Mode Selector is pointing to Fail Lock Set Screw Mode Selector Mode Selector Set Screw L Note The products are intended to be instal...

Page 5: ...r The transformer should only be installed OUTSIDE of the Power Supply Cabinet per all National Electric Code NEC NFPA 70 requirements along with local code requirements and it should be kept in close...

Page 6: ...ently off Do not wire the primary terminals of the transformer until the secondary terminals are connected first The supplied transformer will have its secondary terminals wired to the terminals red w...

Page 7: ...ls in cabinet via wire access hole RED GREEN BLUE Connected to 24V DC from the VDC terminals in the cabinet via wire access hole REM LOC RELAY SPEAKER Wired to the Inside Push to Open terminals in the...

Page 8: ...0 50 seconds The second option d 1 flashing will be how long to wait before activating relay 2 0 15 seconds The third option H 2 flashing will be how long relay 2 will be activated for 0 50 seconds T...

Page 9: ...2 3 ON DP RED GREEN BLUE REM LOC RELAY SPEAKER See the diagrams below for the dip switch functionalities Enable Dip Switch Bank Idle COL Dip Switch Bank Switch number Description Switch number Descrip...

Page 10: ...K THIS DOOR WAIT FOR DOOR TO CLOSE Place sign on the door inside the restroom at eye level INSIDE THE RESTROOM POWER SUPPLY 6 12 24 VDC SMP3 24V OPEN CLSD CLSD OPEN SW1 SW2 6V OPEN OPEN 12V SW1 SW2 AC...

Page 11: ...shown connecting the Push to Open switch to the Push to Open terminals Com Rem PBTN N O Pwr AC DC Com Rem PBTN N O Pwr AC DC IMPORTANT Ensure wiring polarity is consistent from Relay 3 to each remote...

Page 12: ...osing the door or after pushing Push to Lock Logic Module not in Mode 7 Change Logic Module to Mode 7 and ensure all mode 7 settings are set as shown in the instructions No power to the strike Ensure...

Page 13: ...he solenoid releases This can be caused by too much stack pressure on the door pressing on the strike Electric Strike itself is set to Fail Secure rather than Fail Safe Follow the electric strike inst...

Page 14: ...is latching then the door may not fully latch If this occurs the source of the pressure force needs to be removed so that the door can fully close This can be caused by too much stack pressure preven...

Page 15: ...inals Take a jumper wire and touch the screw heads of the PBTN and terminals the actuators wires are hooked up to If the unit acts as if the actuator was actually pushed then either the actuator was w...

Page 16: ...ion DPS switch not closing contact Wiring issue Verify wiring is correct to Power Supply Relay Cabinet and DPS wires fully connected Incorrect mounting Mounting gap should be no more than 3 4 between...

Page 17: ...7 Cabinet base template 9 8 6...