4 ET60 Installation and Operating Instructions
NOTE
Coins and tokens are validated by two coin sensors. Coin sensor 1 validates £1 coins,
L2 and L4 tokens. Coin sensor 2 validates €1, €½, 10p, 20p, L1 token.
St.01 Credit (Fixed Time) Per Coin 1
Sets the amount of credit given by coin sensor 1 (£1 coin, L2 or L4 tokens). Set in
HH.MM or MM.SS.
St.02 Credit (Fixed Time) Per Coin 2
Sets the amount of credit given by coin sensor 2 (€1, €½, 10p, 20p coins or L1 token)
Set in HH.MM or MM.SS.
St.09 Totalise Value
Sets the amount of money that is required before the session starts. If the value is
exceeded, e.g. entering two £1 coins when the required amount is £1.80, the balance
(20p in this example) will be held towards the next session. When the credit remaining
reaches zero this balance is cleared.
St.10 Totalise Credit Value
Sets the amount of time to be given when the correct sum of money has been inserted.
NOTE
In totalise mode single coin mode is invalidated and settings St01 and St02 are unused.
Option settings
Three option settings are available in the ET60; Pre-start, Pre-end and Maximum
Credit.
St.05 Pre-start Value
Pre-start runs prior to the session time allowing the customer time to prepare before the
session starts. This allows customers time to change prior to using a shower or tanning
bed. Entering the required time in setting St.05 enables this feature. The value is
entered in minutes and seconds. Entering zero disables this feature. If the Fascia Start
Button is configured, pressing the start button cancels the remainder of the Pre-start
time and the session commences.
St.07 Pre-end Time
The Pre-end Period is used to give an audible warning before the timer reaches zero.
For example, if the Pre-end time is set to two minutes when the credit remaining
equals five minutes an audible warning is given two minutes before the session is due
to end. Entering the required time in setting St.07 enables this feature. The value is
entered in minutes and seconds. Entering zero disables this feature.
.