background image

309563 03

GB

TR 635 top2

0

6

12

18

24

MENU

OK

TR 635 top2

Connection of 
different external 
wires is permitted

Installation and 
operating instructions

Digital time switch 
with weekly program

TR 

TR 635 top2 

6350100

TR 636 top2 

6360100

D

GB

F

I

E NL

Summary of Contents for TR 635 top2

Page 1: ...2 0 6 12 18 24 MENU OK TR 635 top2 Connection of different external wires is permitted Installation and operating instructions Digital time switch with weekly program TR TR 635 top2 6350100 TR 636 top...

Page 2: ...itial start up 8 Reset 8 Menu item PROGRAM Set switching time 9 Change request switching time 11 Delete switching time 11 Pulse programming 12 Cycle programming 13 Menu item MANUAL Manual and permanen...

Page 3: ...in battery operation Designated use The time switch can be used for lighting bell systems ventilation etc Only use in enclosed dry spaces Do not use on safety devices e g escape route doors fire safet...

Page 4: ...ion Press OK NO Alter change Press OK Store selection Confirm selection Selection options are displayed Date display Date display Channel status ON On OFF Off Days of the week from 1 to 7 Display of a...

Page 5: ...W CHANGE DELETE END MENU TIME DATE MANUAL OPTIONS END TIME DATE SUMMER WINTER DAY OF THE WEEK DATE FORMAT TIME FORMAT END PERMANENT ON PERMANENT OF MANUAL ON TIMER OPERATING HOURS HOLIDAY RANDOM END L...

Page 6: ...nstalled by qualified electrician Disconnect power source Cover or shield any adjacent live components Ensure device cannot be switched on Check power supply is disconnected Earth and bypass TR 635 to...

Page 7: ...tallation wall for installation on DIN top hat rails in accordance with EN 60715 with accessories 9070071 Front panel installation for installation in front frame and transparent cover in accordance w...

Page 8: ...CH RETAIN PROGRAMS DELETE PROGRAMS FORME DATE SU WI GB IRL P SU WI FIN GR TR SU WI CDN SU WI USA SU WI IRAN SU WI FREE RULE SO WI FIX DATE NO SO WI ok or 19 05 11 ON 9 4046 YEAR MONTH DAY FORM TIME HO...

Page 9: ...rm by pressing OK The display shows HOUR Use the or keys to enter hour minute 07 30 and confirm by pressing OK MONDAY is displayed Confirm by pressing OK COPY is displayed Confirm by pressing OK ADD T...

Page 10: ...MENU ON 7 30 PROGRAM NEW SWITCH TIME ON PULSE TUESDAY WEDNESDAY CYCLE END HOUR MINUTE MONDAY COPY ADD TUESDAY SAVE SAVE 84 memory locations are available 10...

Page 11: ...firm by pressing OK NEXT is displayed Change or delete individual switching times Press to select MODIFY or DELETE Confirm MODIFY HOUR by pressing OK Confirm by pressing OK The first of the entered sw...

Page 12: ...yed Select PULSE by pressing u Confirm by pressing OK ON is displayed Confirm by pressing OK The display shows HOUR Use the or keys to enter hour minute second 8 05 and confirm by pressing OK PULSE LE...

Page 13: ...rs to cyclically repetitive time functions such as fan controls urinal rinses etc Example Switch on water rinsing Monday from 8 00 to 20 30 hrs every 15 min for 20 sec 8 0000 8 0020 On 8 1500 8 1520 O...

Page 14: ...tching Briefly press both keys simultaneously Activate permanent switching Simultaneously press both keys for 2 seconds Cancelling manual permanent switching Press both keys simultaneously ok Enter PI...

Page 15: ...mory card OBELISK top2 No 9070404 after copying Avoid mechanical stress or dirtying with other storage transport methods Serviceadresse Hotline Service address Theben AG Hohenbergstr 32 72401 Haigerlo...

Page 16: ...ad 2300 W TR 635 top2 1200 W TR 636 top2 Fluorescent lamp load uncorrected VVG series corrected 1000 VA parallel correction 400 VA 42 F Compact fluorescent lamps 90 W LED lamps 2 W output max connec t...

Reviews: