Installation and maintenance manual lba12
25
Reversibilite
Option to be activated when the barrier is
reversible in order to activate the "holding
torque" function
(TRUE: activated; FALSE: deactivated)
●
Reouverture_secu
Activation of the automatic reopening on
detection of a safety component (loops, IR
cell, ultrasound, etc.)
(TRUE: activated; FALSE: deactivated)
●
Param_Boost_1
Value of the boost applied to the motor
during movement
%
●
Param_Boost_2
Speed below which a boost is applied to the
motor in movement
Hz
●
Param_Boost_3
Value of the boost applied to the motor
during holding torque
%
●
Param_Boost_4
Speed below which a boost is applied to the
motor in holding torque
Hz
●
Param_Motor_1
Maximum value of the current that can be
applied to the motor during movement
A
●
Param_Motor_2
Maximum value of the current that can be
applied to the motor during holding torque
A
●
Param_Motor_3
Choice of the motor to control:
1: Motor 0.18kW 1.2A Bonfiglioli
2: Motor 0.25kW 1.5A Leroy Somer
3: Motor 0.55kW 3A Bonfiglioli
4: Motor 0.25kW 1.4A Bonfiglioli
●
Sens_barriere
Direction of rotation of the motor
(1; -1)
●
Note: This is a default list. It can change according to the type of barrier and customer.
Important : The settings in grey must not be modify without contacting the after-sale service.
Modification of a setting:
To modify a setting in the PLC, you must:
1-
Using the directional arrows and the "Enter » key, select the setting that you want to
modify. The value is displayed.
2-
Press "Enter" again to be able to modify the value
3-
Set the desired value using the up and down arrows.
4-
Press "Enter" again to confirm
5-
Then press "ESC" to return to the list of parameters
6-
Press "ESC" again to exit the menu
o
"IP CONFIG" - IP address configuration:
See §5 TCP/IP Modbus Communication
=Vitesse_OUV=
70
Up(Next)/Down(Prev)
Enter => Edit value
=== USER PARAM ===
Vitesse_OUV [*]
Vitesse_FERM [ ]
Petite_vit_OUV [ ]