Installation and maintenance manual lba12
14
5.3
Electrical and control connection
The supply voltage for the barrier is 230 V ± 10%, 50 Hz ± 2 Hz monitor phase
according to NFC 15-100.
Power cuts lasting less than 100 ms will not affect operation.
The barrier must be supplied by a 3G 1.5mm² or 2.5mm² cable (depending on the
length of the cable).
Electrical protection should be provided at the head of the line (10A-30mA differential
circuit breaker per barrier)
Connection of the barrier must be carried out without power.
The supply cable and the Earth must be connected to the terminal block intended for
this purpose (see electrical diagram).
The control cable must be connected to the terminal block intended for this purpose
(see electrical diagram).
5.4
Posing and positioning the equipment
5.4.1
Mounting the arm:
The arm is mounted following the procedure:
A
– Turn off power supply to barrier
B
– Unscrew the screws on the half-shell mounts (on each side)
C
– Insert the rail until it is in contact with the end of the half-shell mount
D
– Insert the 4 screws and nuts that allow the rail to be held within the half-shell
mounts
E
– Re-tighten the half-shell mount fixings
E
D
B
C