16
For HELP, call La-Z-Boy
®
Spas at 1.800.465.2933.
Electrical Specifications
120V to 240 V Conversion
(North America 60hZ)
Some spa owners choose to have their spa converted
from 120V operation to 240V operation for greater energy efficiency.
WARNING: The electrical circuit must be installed by a licensed
electrical contractor and approved by a local building or electrical
inspector. Failure to comply with state and local codes may result in
fire or personal injury and will be the sole responsibility of the spa
owner.
The steps to converting your spa from 120V to 240V operation are shown below
and must be completed by a licensed electrician.
Power supply installation must include a properly rated GFCI circuit breaker. The
circuit must be dedicated and should not be shared with any other appliances. It
should be labeled and easily accessible to users. The power supply must be hard
wired into the power pack. A hole may be drilled through the resin cabinet near the
electrical pack to accommodate wiring. Foam insulation may be sprayed around the
hole to fill any gaps between the cabinet and the wiring.
Step 1.
Disconnect jumper form J11
Step 2.
Disconnect the other end of the same
jumper form J33