11
10
AirSpa
®
10-Motor Massage & Heat Recliner
Programming Instr uctions:
The Program feature provides the a bility to program the intensity levels of the
vibrating massage motor s in each zone.
To Use The Program Feature
1. Press
PRGM
to activate the feature (the light will star t blinking).
2. Press
ZONE 1
, Upper Back, and set the intensity level desired.
•
Press + Intensity to increase the intensity level.
•
Press - Intensity to decrease the intensity level.
3. Press
ZONE 2
, Lower Back, and set the intensity level desired.
4. Press
ZONE 3
, Hip Region, and set the intensity level desired.
5. Press
ZONE 4
, Upper Thigh, and set the intensity level desired.
6. Press
ZONE 5
, Lower Thigh, and set the intensity level desired.
7. Press
PRGM
to use the set intensity program that you just selected, w hich can
be used with any ZONES selected and in any mode—PULSE, WAVE and CIRCLE
(the light will stop blinking).
8. Press
PRGM
again to deactivate the set intensity program mode and retur n to
the default settings (the light will tur n off).
Your program remains in memor y until you set a new program. To activate the set
program ag ain:
1. Press
PRGM
to activate the feature (the light will star t blinking).
2. Press
PRGM
again to use the last programmed setting (the light will stop blinking).
3. Press
PRGM
again to deactivate the feature and retur n to the default settings
(the light will tur n off).
NOTE:
A power disruption, such as an electrical power outage, may cause the
program to return to the default settings.
AIRSPA
®
10-MOTOR MASSAGE & HEAT RECLINER TRANSFORMER SPECIFICATIONS:
Input: 120V AC 60 Hz 65 W
Output: 12V AC 4170mA
Save These Instr uctions
AirSpa
®
10-Motor Massage & Heat Recliner
Operating Instr uctions:
POWER
Activates system w hen button is
backlit with green LED. Press once
for 15-min. timer. Press and
hold down for 30-min. timer.
NOTE:
To restart unit after
timer shuts off, press
either ZONE or PWR button.
ZONES
Activates any or all zones .
Green LED indicates w hich
zone(s) has been selected.
PULSE MODE
Activates 3 pulse settings .
PULSE, TAP and ALT.
(alter nating pulse & ta p)
in active zones .
INTENSITY
Will increase (+) or
decrease (-) intensity
dur ing all modes .
INFLATE
Will increase the pressure
of the lumbar suppor t.
This may be operated
independently or in
conjunction with the
LOWER feature.
NOTE:
When the system is
activated, lumbar support
automatically inflates for
3 seconds before pressure
can be adjusted.
POWER
LED indicates w hen AirSpa
®
System is activated.
NOTE:
Air massage will deactivate in
30 minutes. To restart unit after timer
shuts off, press the PWR button.
HEAT
Activates heat. Press once
for low and twice for high.
NOTE:
Heat will deactivate
in 30 minutes. To restart,
press the HEAT button again.
WAVE MODE
Activates 3 wave-like
settings (1-5-1, 1-5 or 5-1)
in active zones .
CIRCLE MODE
Activates clockwise (CW),
counterclockwise (CCW)
or figure 8 (FIG 8) patter n
in active zones .
SPEED
Controls pulsing frequency
of massage in PULSE
mode and controls
velocity as it cycles
through in WAVE mode.
PROGRAM
Provides a bility to program
intensity levels in each zone.
See Programming
Instructions.
SWELL
Increases and decreases
intensity cycling in all
modes . Use FAST and SLOW
to adjust speed of intensity.
LOWER BACK
Controls inflation and
deflation volume rate for
the lower lumbar
area air pillows .
Select OFF, LOW, MED, HIGH
NOTE:
System will be at MED
setting when activated.
DEFLATE
Will decrease the pressure
of the lumbar suppor t. May
be operated independently
or in conjunction with the
LOWER feature.
1
Upper Back
2
Lower Back
3
Hip Region
4
Upper Thigh
5
Lower Thigh
–
To reduce the risk of serious injur y:
•
Do not use unit if power control is damaged or wet. Do not use unit if the
hand wand has been dropped in water or any liquid. Contact your
La-Z-Boy
®
dealer for service.
WARNING