AirSpa
®
10-Motor Massage & Heat Recliner
Assembly Details:
F
I G U R E
1
Body
Bracket
Back Bracket
Back
Bracket
Locking
Lever
Locked
Position
F
I G U R E
3
Back and body brackets on this
side are not engaged. Remove
the back and reinstall.
7
6
1. Install the back.
•
Lay the back across the chair ar ms . Lift the back at a slight angle and align
the brackets on the back with the brackets on the body (F
I G U R E
1).
•
Lower the back onto the body, making sure the back and body brackets are
completely engaged.
•
To make sure the back is proper ly installed, with both sets of back
and body brackets engaged, stand behind the chair and twist the
back from side to side. If one or both sides move out of position
the brackets are not engaged (F
IGURE
2). Remove the back and
repeat the steps a bove.
•
If you are unable to install the back properly contact your La-Z-Boy
®
dealer for assistance.
•
Lock the brackets by using a screwdriver to push down the locking levers (F
IGURE
3).
2. Locate the massage connector s .
•
Stand at the side of the chair and push the back rearward to recline the
seat and back.
•
Gently roll the chair forward to rest on its ar ms and the top of the back,
revealing the under side of the chair and the connector s .
3. Identify the three connections you will make.
•
Locate the five wires with connector s . Four wires are located next to the
rear body rail. One wire is located next to the body side panel; if the chair
has an ar m storage compar tment it is located on the r ight side and if the
chair has an ar m storage pocket it is located on the left side.
•
The two square connector s are the Vibrating Motor connector s (F
IGURE
4).
•
The one small round connector is the Power Transfor mer connector (F
IGURE
4).
•
The two large round connector s with w hite dots are the Hand Wand
connector s (F
IGURE
4).
4. Connect the Vibrating Motor s .
•
Align the two square Vibrating Motor connector s and push the connector s
together until they lock (F
IGURE
5).
5.
Connect the Hand Wand.
•
Align the white dots on the Hand Wand connectors and push the connectors
tightly together (F
IGURE
5).
(Assembly Instructions Continued)
AirSpa
®
10-Motor Massage & Heat Recliner
Assembly Instr uctions:
–
To reduce the risk of injur y:
•
Do not operate the unit until the back is installed and locked.
NOTICE:
Do not plug the transformer in until instructed.
F
I G U R E
2
Vibrating Motor
Connector s
Hand Wand
Connector s
Power Transfor mer Connector
F
I G U R E
5
Power Transfor mer
Connector
Vibrating Motor
Connector s
Hand Wand
Connector s
F
I G U R E
4
WARNING