Electrical Specifications
120 Volt Electrical Installation
(North America 60hZ)
Always follow applicable local, state and
federal codes and guidelines.
• Use a dedicated electrical line with a 15A
breaker.
• Cord-and-plug connections may not use a cord
longer than 15 feet (4.6 m) and must be plugged
into a dedicated 15A GFCI connection (NEC
680.42(A)
• Do not use extension cords!
• Always use a weatherproof-covered receptacle.
• Receptacle shall be located not less than 5 feet
(1.5 m) from and not exceeding 10 feet (3.0 m)
from the inside wall of the spa. (NEC 680.43(A))
• Do not bury the power cord. If your cord
becomes damaged, replace it before next usage.
• All 120V spas use a GFCI cord and plug as
shown.
• Test the GFCI plug prior to first use and
periodically when the spa is powered. To test the
GFCI plug version, follow these instructions. (Spa
should already be plugged in and operational.)
1. Press the TEST button on the GFCI. The GFCI
will trip and the spa will stop operating.
2. Press the RESET button on the GFCI. The
GFCI will reset and the spa will turn back on.
The spa is now safe to use.
• If the GFCI trips while the spa is in use, press
the RESET button. If the GFCI does not reset,
unplug the spa and call your local La-Z-Boy Spas
dealer for service. DO NOT USE THE SPA!
IF USING THE STANDARD 120V SERVICE, YOU MUST USE A DEDICATED LINE, WHICH MEANS THAT
THERE CANNOT BE ANY OTHER HOUSEHOLD ITEMS CONNECTED TO THE CIRCUIT OR OUTLET AT ALL!
HAVINGANY OTHER ELECTRICAL APPLIANCES AT ALL ON THIS CIRCUIT WHILE THE SPA IS RUNNING
WILL TRIP THE BREAKER IMMEDIATELY. DO NOT USE ANY TYPE OF EXTENSION CORDS BETWEEN THE
SPA AND THE WALL OUTLET, THIS WILL ALSO CAUSE THE BREAKER TO TRIP AND CAN BE A
POTENTIAL FIRE HAZARD.