For HELP, call La-Z-Boy
®
Spas at 1.800.465.2933.
Diagnostic Messages
Possible inadequate water, poor
flow, or air bubbles in detected in
the heater. Spa is shut down for 15
minutes.
If water level is normal, make sure all
pumps have been primed. Press any
button to reset. This message will reset
within 15 minutes. If problem persists,
contact your dealer or service
organization.
Inadequate water detected in heat-
er. (Displays on third occur-
rence of message.) Spa is shut
down.*
Follow action required for message. Spa
will not automatically reset. Press any
button to reset manually.
“Ice” - Potential freeze condition
detected.
No action required. All equipment will
automatically activate regardless of spa
status. The equipment stays on 4
minutes after the sensors detect that the
spa temperature has risen to 45°F/7.2°C
or higher. An optional freeze sensor may
be added to protect against extraordi-
nary freeze conditions. Auxiliary freeze
sensor protection is advisable is colder
climates. See your dealer for details.
Mess Meaning
Action
Required