To achieve redundant control, you must use both interfaces.
If you are using in-band control, then the management ports are addressed via the media ports/network (and the physical
MGMT ports can be left unconnected).
To use the network ports, you must fit the correct optical transceivers. These must be Lawo-certified (as described earlier).
The optical transceiver determines the cable type, maximum distance and connector.
4. SDI Interfaces (48 x HD-BNC)
5. Reference Interfaces (5 x HD-BNC)
For external synchronization, there are 5 x HD-BNC connectors: 2 x REF IN, 2 x REF THRU and 1 x REF OUT.
The two reference inputs can be used to connect up to two external sync reference signals. In each case, the THRU
connector provides a "looped-through" output of the corresponding IN.
The REF OUT is always active and provides an output of the current reference: External IN 1, External IN 2, PTP or
Internal (free-run).
The current reference can be changed using the HOME Web UI. For more information, see .edge - Synchronization.
6. Grounding Screw (M5x12)
A grounding screw is provided on the right side of the frame (when viewed from the rear). See
for more
information about the safety requirements.
Summary of Contents for edge
Page 43: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 43 154...
Page 58: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 58 154...
Page 98: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 98 154...
Page 103: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 103 154...
Page 113: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 113 154...
Page 126: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 126 154...
Page 130: ...edge User Manual Version 1 0 13 1 Exported on 22 February 2024 130 154...