8
A STEELFORT PRODUCT
OVERCURRENT PROTECTOR
When the generator is overloaded or overheated for
a long time, the overcurrent protector will disconnect
the output; in this case, please re reduce the load
or run it under no load for a few minutes, and then
press the overcurrent protector button to restore the
output.
Note: The overcurrent protector is relevant to the
operating current, ambient temperature and other
factors, so the protection time will be different.
COMBINATION SWITCH
Start (If Equipped Recoil Start): Close the choke
Run: The Generator works normally.
Note: After the generator is unloaded, please run for
3 minutes with no load to stabilize the temperature,
then stop the generator.
SHUT Off: Fuel shut off valve. This position can run
out of the remaining fuel to ensure old fuel is not
present when generator has not been used for long
periods.
Note: If you do not plan to use the generator in the
near future, please use this function, or drain the
fuel inside the carburettor using the drain bolt on the
carburettor bowl.
FLAME OUT: The Generator stops working
Note: After the load is removed from the generator,
please run the generator under no load for 3 minutes
to balance the temperature, and then activate the
flameout function
LGP FEMALE CONNECTOR
(IF APPLICABLE)
Open the LPG waterproof cover, align the male joint
of the relief valve pipe with the LPG female joint and
insert it until a click is heard, indicating that the relief
valve is firmly connected. After the relief valve is
firmly connected, the carburetor will stop supplying
fuel and the generator can only use fuel at this time.
NOTE: If the generator needs to use the fuel, please
close the fuel cylinder valve and disconnect the relief
valve from the generator, and then the generator can
use the fuel normally.