15
A STEELFORT PRODUCT
WARNING
It is necessary to equip with circuit protector or
switch to isolate the generating set from the electric
utility when the generating set is mainly 1,1sed for
backup. Failure to isolate the generating set from the
power utility may result in injury or death to electric
utility workers and damage to the generating set due
to back feed of electrical energy.
STOPPING THE ENGINE
Turn off the electrical devices and then unplug all the
electrical device plugs from the panel.
WARNING
NEVER stop the engine with electrical devices
connected and with the connected devices turned
“ON”.
STOP USING GASOLINE
•
Turn the combination switch to “SHUT-OFF”
position. Let the generator burn off the excess
fuel in the fuel circuit, and the generator will be
automatically shut down.
•
Turn the combination switch to “FLAMEOUT”
position.
WARNING
The generator is idle for a long time:
If the generator needs to be idle for a long time,
please turn the fuel cock to “Shut-off’ position.
Turn the combination switch to "Flameout" position
until the fuel in the carburetor oil cup burns out
and the generator has an automatic flameout.
If the combination switch is not turned to "FLAME-
OUT" position and the battery is not in use for a
long time, it will lose power, resulting in failure to
start the generator normally.
STOPPING WHEN USING LPG
(IF APPLICABLE)
1.
Let the generator run without load for 3 min
to stabilize the internal temperatures of the
engine and the generator.
2.
Close the fuel cylinder valve.
3.
Turn the combination switch to “FLAMEOUT”
position.
4.
Remove the relief valve from the generator
LPG female joint and cover it with the shield.
VIII. MAINTENANCE
It is the operator’s responsibility to complete all
scheduled maintenance and or servicing in a timely
manner. Always correct any issues before operating
the generator. Follow all inspection and
maintenance recommendations that are listed in the
manual.