Empty the fuel tank before storing or    

transporting the generator. Keep fire    

extinguisher handy at all times. 

BATTERY

• 

Lithium battery is maintenance free, if you have 

any question, please contact a local LawnMas-

ter dealer.

HOT SURFACE

• 

Running the generator will produce heat and 

severe burns may occur upon contact. DO NOT 

touch the engine while under operation or just 

after stopping the unit. 

• 

Avoid contact with hot exhaust gases and or 

hot surfaces. 

• 

Maintain at least 1m of clearance on all sides to 

ensure adequate cooling. Combustible material 

can catch fire upon contact. Maintain at least 

3m of clearance from combustible materials.

MOVING PARTS

• 

Moving parts can cause severe injury. Keep 

hands and feet away from the unit. 

• 

DO NOT operate engine with covers, shrouds, or 

guards removed. 

• 

DO NOT wear loose-fitted clothing, dangling 

drawstrings or items that could become caught 

or entangled. 

• 

Tie up long hair and remove jewelry. The  

moving parts may catch operator’s hand, feet, 

hair and or loose clothing resulting in serious 

injury.

GENERAL WARNINGS

• 

Before use, check for loose or damaged parts, 

signs of oil or fuel leaks, and any other    

condition that may impact operation. 

• 

Repair or replace all damaged and or defective 

parts immediately. 

• 

Locate all operating controls and safety labels. 

• 

Make sure all the safety instructions are in 

correct working condition. 

• 

Operate only on level surfaces. 

• 

DO NOT expose the generator to excessive 

moisture, dust, and or dirt. 

• 

Keep all safety guards in place and in proper 

working order at all times. 

• 

DO NOT allow any material to block the cooling 

slots. 

• 

DO NOT allow children or untrained people to 

operate the unit. 

• 

DO NOT leave the generator unattended when 

it is in operation. Always turn off the generator 

prior to leaving the area.

ELECTRIC SHOCK

• 

The generator produces powerful voltage and 

the electricity and can be dangerous and cause 

serious life threatening injuries if an electric 

shock is received. 

• 

Please ensure that the unit is properly    

connected to an appropriate ground to help 

prevent electric shocks. 

• 

Failure to properly ground the unit can result 

in electrocution, especially if the generator is 

equipped with a wheel kit. Consult an   electri-

cian for local grounding requirements. 

• 

Installation should be performed by a certified 

electrician. Improper Installation could result in 

serious injury. 

• 

To reduce the risk of electric shocks. DO NOT 

use electrical cords that are worn, frayed, bare 

or otherwise damaged. 

• 

DO NOT touch bare wires or receptacles. 

• 

DO NOT operate the unit in wet weather. 

• 

Keep the generator dry and DO NOT handle 

generator or electrical cords while standing in 

water, while barefoot, or while hands or feet 

are wet. 

• 

Keep children or pets away.

• 

DO NOT plug the unit into a building electrical 

system without the proper use and installation 

of a transfer switch installed by a qualified 

electrician.

• 

When using the generator for backup power, 

notify your utility company. 

• 

Use approved transfers to isolate generator 

from electric utility. 

• 

Failure to isolate the unit from the power utility 

could result in serious injury to the staff and 

utility workers due to back-feed of electrical 

energy.

GETTING STARTED

UNPACKING

Remove the generator from the packaging

1. 

Place box on a solid and flat surface

2. 

Carefully cut each corner of the packaging box 

from top to bottom. Lay each side open and flat 

on the ground.

3. 

Remove all accessories except the generator 

from the packaging box.

Summary of Contents for LGBQH6200

Page 1: ...SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT SILENTINVERTER GENERATOR PROUDLY NZ OWNED A STEELFORT PRODUCT LGBQH6200 E...

Page 2: ...ounding LGP Cylinder Check Inspection Of Connection With LGP STARTING THE GENERATOR 11 Recoil Start Electric Start LGP CONNECTING TO THE ELECTRICAL DEVICES 14 Loading Capacity Wattage Reference Chart...

Page 3: ...ial use may void warranty These generators are designed for full time operation No personal modifications should be made to any part of the unit DANGER TOXIC FUMES The exhaust of the engine contains c...

Page 4: ...untrained people to operate the unit DO NOT leave the generator unattended when it is in operation Always turn off the generator prior to leaving the area ELECTRIC SHOCK The generator produces powerfu...

Page 5: ...nel when installing the right maintenance panel back into place USAGE OF HANDLE CAUTION Make sure the generator is placed on a level ground before using the handle After the handle button is pressed t...

Page 6: ...rt Handle 11 Combination Switch Start If Equipped Run Shut Off And Flameout 12 Right Maintenance Panel 13 Rear Lift Handle 14 Muffler Screen 15 Muffler 1 Overcurrent Protector 2 AC Output 3 Ground Ter...

Page 7: ...gine automatically and oil alarming lamp will blink when recoil starter is pulled The engine will not run until the oil has been filled to the proper level Note If engine stalls or fails to start turn...

Page 8: ...not present when generator has not been used for long periods Note If you do not plan to use the generator in the near future please use this function or drain the fuel inside the carburettor using th...

Page 9: ...at altitudes above 5 000 feet 1 500 meters CAUTION Even with carburetor modification generator horsepower will decrease by 3 5 for every 1 000 feet 300 meters increase in altitude The effect of altitu...

Page 10: ...eposits from forming in essential fuel system components such as the carburetor fuel filter fuel hose or tank during longterm storage Also experience indicates that alcohol blended fuels gasohol ethan...

Page 11: ...leaks If bubbles appear and become larger it indicates that any connector is not installed in place or is damaged resulting in leakage Please close the fuel cylinder valve and turn off the generator i...

Page 12: ...l be started and the start button will be reset automatically WARNING When the generator cannot be started through electric start due to low battery power which is caused by generator idling for a lon...

Page 13: ...he generator after using other batteries without authorization STARTING THE GENERATOR WITH LGP IF EQUIPPED 1 Perform pre use inspection items and remove all loads 2 Connection steps of relief valve as...

Page 14: ...e risk of electrical shock DO NOT use electrical cords that are worn frayed bare or otherwise damaged DO NOT touch bare wires or receptacles DO NOT handle generator or electrical cords while standing...

Page 15: ...enerator is idle for a long time If the generator needs to be idle for a long time please turn the fuel cock to Shut off position Turn the combination switch to Flameout position until the fuel in the...

Page 16: ...DULE Before servicing the generator stop the gen erator disconnect all electric devices and battery if equipped and allow the generator to cool down Follow the service intervals indicated in the chart...

Page 17: ...n the average temperature in your area is within the indicated range OIL MUST BE PLACED IN ENGINE BEFORE STARTING Ambient temperature Oil capacity rated See Parameters 3 2 ADDING OIL WARNING The engin...

Page 18: ...nt 3 Wash in liquid detergent and warm water 4 Squeeze thoroughly dry in a clean cloth 5 Saturate in clean engine oil 6 Squeeze in a clean absorbent cloth to remove all excess oil 7 Place the filter i...

Page 19: ...mpletely before servicing the spark arrester 2 Remove the muffler blind window first 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wir...

Page 20: ...ecoil starter slightly to distribute the oil and lubricate the cylinder And then attach the spark plug 7 Store the unit in a clean dry area out of direct sunlight 8 Disconnect the battery TRANSPORTATI...

Page 21: ...21 A STEELFORT PRODUCT TROUBLE SHOOTING...

Page 22: ...PRODUCT SPECIFICATIONS WIRING DIAGRAMS 1 SPECIFICATION PARAMETER TABLE Note The generating set with different specification and configurations may have different parameters and may change at any time...

Page 23: ...23 A STEELFORT PRODUCT 2 WIRING DIAGRAMS BQH6200E ELECTRIC START Note This circuit diagram is for reference only due to the generator set condition difference...

Page 24: ...f purchase documentation are required and must include the engine serial number and frame serial number as appropriate for all warranty claims Authorised LawnMaster dealers are able to repair and or r...

Page 25: ...s that are incurred in the warranty claim for additional expenses such as towing communications accommodation and meals that are incurred due to the breakdown of the product at a remote location are n...

Page 26: ...0 Rangitikei Street Private Bag 11045 Palmerston North 4412 New Zealand 06 350 1350 Steelfort Auckland 880 Great South Road Penrose Auckland 1061 New Zealand 09 573 1324 lawnmasternz FIND US www lawnm...

Reviews: